مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

845
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

MITIGATING NEGATIVE SEQUENCE CURRENT OF ISLANDED SMALLSCALE SYNCHRONOUS GENERATOR USING AN INVERTER-BASED RESOURCE

Pages

  55-64

Abstract

 The load unbalance is one of inherent features of distribution systems which draws a negative sequence current from islanded synchronous generators.This leads to overheating of the stator and, in particular, the rotor core. In such a case, it is not possible to operate the generator at its associated rated power. Thus, implementing an inverter-based resource in parallel with the synchronous generator is the main strategy proposed in this paper to tackle such a problem. To do so, the negative sequence of the reactive power is measured, and the output voltage of the inverter is regulated using a resonance controller in the abg reference frame such that its injected negative sequence current makes the generator voltage balance, as much as possible. Investigations performed in this paper show that based on the proposed method, the inverter can rapidly and effectively compensate the load unbalance in the distribution system. Accordingly, the generator current is also balanced, and thus, there is no need to limit the synchronous generator output power. Moreover, it is not necessary to overdesign the synchronous generator for unbalanced load conditions. As a result, the islanded mode synchronous generator can also be operated in a distribution system with unbalance loads without considerable derating.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SAMIMI, MOHAMMAD HAMED, & DAVARPANAH, MAHDI. (2018). MITIGATING NEGATIVE SEQUENCE CURRENT OF ISLANDED SMALLSCALE SYNCHRONOUS GENERATOR USING AN INVERTER-BASED RESOURCE. JOURNAL OF IRANIAN ASSOCIATION OF ELECTRICAL AND ELECTRONICS ENGINEERS, 15(1 ), 55-64. SID. https://sid.ir/paper/115717/en

    Vancouver: Copy

    SAMIMI MOHAMMAD HAMED, DAVARPANAH MAHDI. MITIGATING NEGATIVE SEQUENCE CURRENT OF ISLANDED SMALLSCALE SYNCHRONOUS GENERATOR USING AN INVERTER-BASED RESOURCE. JOURNAL OF IRANIAN ASSOCIATION OF ELECTRICAL AND ELECTRONICS ENGINEERS[Internet]. 2018;15(1 ):55-64. Available from: https://sid.ir/paper/115717/en

    IEEE: Copy

    MOHAMMAD HAMED SAMIMI, and MAHDI DAVARPANAH, “MITIGATING NEGATIVE SEQUENCE CURRENT OF ISLANDED SMALLSCALE SYNCHRONOUS GENERATOR USING AN INVERTER-BASED RESOURCE,” JOURNAL OF IRANIAN ASSOCIATION OF ELECTRICAL AND ELECTRONICS ENGINEERS, vol. 15, no. 1 , pp. 55–64, 2018, [Online]. Available: https://sid.ir/paper/115717/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button