مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

977
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Environmental impact assessment of cathode copper factory establishment using flash furnacemethod in Sungun copper complex

Pages

  123-136

Abstract

 Introduction: In order to reduce environmental hazards, Environmental Impact Assessment (EIA) is a legal requirement for the construction of metal processing and production factories. The purpose of this study was to assess the environmental impacts of the establishment of Sungun Cathode copper factory using flash furnace method and also its compatibility with the environment was studied in this research. Civil part of the factory is under construction in the north of East Azarbaijan Province and is adjacent to Sungun copper mine. The location of the project site is in the vicinity of the Arasbaran Protected Area and is therefore important in terms of environmental impact in the area. Material and methods: In this study, at first library studies were carried out and then, data and information on Environmental Impact Assessment were collected by relevant experts, and eventually the Iranian version of the Leopold Matrix (modified Leopold) was selected as the evaluation method. Next, activities during the construction phase and environmental parameters in each of the physical, biological, and socio-economic and cultural aspects of the project were determined. Then, project activities and environmental parameters were placed in columns and rows of the matrix, respectively. This matrix was bearing cells containing two values of amplitude and magnitude of the impact. The numeric value for amplitude was 1-5 and for magnitud was 5+ to 5. With the production of two amplitude and magnitude, the final score was obtained for each cell with positive or negative scores. The mean scores for each row and column of the matrix were calculated, based on which conclusions were made for the matrix. Results and discussion: In this study, at first library studies were carried out and then, data and information on Environmental Impact Assessment were collected by relevant experts, and eventually the Iranian version of the Leopold Matrix (modified Leopold) was selected as the evaluation method. Next, activities during the construction phase and environmental parameters in each of the physical, biological, and socio-economic and cultural aspects of the project were determined. Then, project activities and environmental parameters were placed in columns and rows of the matrix, respectively. This matrix was bearing cells containing two values of amplitude and magnitude of the impact. The numeric value for amplitude was 1-5 and for magnitud was 5+ to 5. With the production of two amplitude and magnitude, the final score was obtained for each cell with positive or negative scores. The mean scores for each row and column of the matrix were calculated, based on which conclusions were made for the matrix. Conclusion: Environmental assessment of the construction of a Cathode copper processing plant using Flash Furnace was rejected because of the large volume of contamination even after two environmental reforms. Therefore we propose that, the athouriteis of the factory examin the possibility of other methods to produce Cathode copper including hydromeatalurogic methods and a new introduced technology named SKS.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HATAMI, MARYAM, Vaezihir, Abdorreza, & Hasanpour Sedghi, Mohammad. (2019). Environmental impact assessment of cathode copper factory establishment using flash furnacemethod in Sungun copper complex. ENVIRONMENTAL SCIENCES, 17(2 ), 123-136. SID. https://sid.ir/paper/117650/en

    Vancouver: Copy

    HATAMI MARYAM, Vaezihir Abdorreza, Hasanpour Sedghi Mohammad. Environmental impact assessment of cathode copper factory establishment using flash furnacemethod in Sungun copper complex. ENVIRONMENTAL SCIENCES[Internet]. 2019;17(2 ):123-136. Available from: https://sid.ir/paper/117650/en

    IEEE: Copy

    MARYAM HATAMI, Abdorreza Vaezihir, and Mohammad Hasanpour Sedghi, “Environmental impact assessment of cathode copper factory establishment using flash furnacemethod in Sungun copper complex,” ENVIRONMENTAL SCIENCES, vol. 17, no. 2 , pp. 123–136, 2019, [Online]. Available: https://sid.ir/paper/117650/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top