مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

831
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

VALIDATION OF THE LINAC VARIAN SIMULATED USING BEAMNRC CODE FOR 6MV PHOTON ENERGY

Pages

  551-561

Abstract

 Background and Objective: Simulation using Monte Carlo technique is a practical method for assessment of the characteristics of the clinical photon beam from the treatment head. The accuracy of the simulation results is based on the VALIDATION of the Monte Carlo models used in the calculation. This study validated the simulation with BEAMnrc code for 6MV energy.Subjects and Methods: The accelerators of Varian Clinic 2100C/D for photon beam 6MV were simulated using the BEAMnrc code system. A cylindrical mono energetic with 5.7, 5.9, 6 MV energies and 1, 2, 3 mm radius were applied. Two phase space files were scored below the exit window and above the phantom then analyzed the beam characteristics using BEAMdp and calculated the percentage depth dose and profile at 10cm using DOSXYZ code. In this work, measurements were performed using 0.13 cc ion chamber inside a water phantom with dimension 50×50×50cm3. At the end of simulation, the results of the measured data were compared using gamma index with criteria 2%/2mm.Result: By increasing the electron energy, percentage depth dose in buildup region was reduced and became closer to measurements. With increasing the diameter of the electron source, the photons were diverged and the edges of the profiles showed a sharp drop compared to the dose measurements.Conclusion: Finally good agreement (gamma index within2%/2mm) between the measurements and simulations was achieved for field sizes of 4×4 ,10×10 and 30×30cm2 with radial of incident electrons 0.2cm at source surface distances of 100cm.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    CHEGENI, NAHID, ABOLMAALI AL HOSSEINI, KHADIJEH, SHAHBAZIAN, HOJATTOLLAH, MASKANI, REZA, HOSEINI GHAFAROKHI, MOJTABA, MIRKHAGHANI, FARZANEH, & RAJA ESKANDARI, SOUDABEH. (2016). VALIDATION OF THE LINAC VARIAN SIMULATED USING BEAMNRC CODE FOR 6MV PHOTON ENERGY. JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL, 15(5), 551-561. SID. https://sid.ir/paper/12656/en

    Vancouver: Copy

    CHEGENI NAHID, ABOLMAALI AL HOSSEINI KHADIJEH, SHAHBAZIAN HOJATTOLLAH, MASKANI REZA, HOSEINI GHAFAROKHI MOJTABA, MIRKHAGHANI FARZANEH, RAJA ESKANDARI SOUDABEH. VALIDATION OF THE LINAC VARIAN SIMULATED USING BEAMNRC CODE FOR 6MV PHOTON ENERGY. JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL[Internet]. 2016;15(5):551-561. Available from: https://sid.ir/paper/12656/en

    IEEE: Copy

    NAHID CHEGENI, KHADIJEH ABOLMAALI AL HOSSEINI, HOJATTOLLAH SHAHBAZIAN, REZA MASKANI, MOJTABA HOSEINI GHAFAROKHI, FARZANEH MIRKHAGHANI, and SOUDABEH RAJA ESKANDARI, “VALIDATION OF THE LINAC VARIAN SIMULATED USING BEAMNRC CODE FOR 6MV PHOTON ENERGY,” JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL, vol. 15, no. 5, pp. 551–561, 2016, [Online]. Available: https://sid.ir/paper/12656/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top