مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

756
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

DETERMINING THE EFFECT OF SOURCE SURFACE DISTANCE VARIATIONS ON PERCENTAGE DEPTH DOSE IN ISOCENTRIC RADIATION THERAPY WITH 6MV PHOTONS

Pages

  317-326

Abstract

 Background and Objective: The PERCENT DEPTH DOSE (PDD) is used as a dose calculation method in radiation therapy. PDD varies with SOURCE SURFACE DISTANCE (SSD) according to inverse square law. In most clinical situations it is necessary to convert standard SSD to that must be used in practice. Therefore; this research proposes a new factor to calculate PDD corresponding to SSD.Materials and Methods: Electa compact accelerator for 6MV photon beam, Scanditronix blue phantom the size of 50 ×50 ×50cm3 and two ionization chamber with sensitive volume of 0.13 cc were used. Dosimetry was done for field sizes: 8×8, 10×10, 6.4×6.4 cm2 at SSD=80 and 100cm. Ks0 and Ks taking into account the collimator SCATTER, for fields in the standard SSD and the practical SSD, respectively. The ratio of Ks0 and Ks was applied to correct the Maynord F factor. Results: This corrected Maynord F factor revealed better results for 8×8 and 10×10 cm2 fields further more the corrected Maynord F factor, reached the more precision in buildup region for the 6.4×6.4 cm2 field for PDD calculations.Conclusion: For small fields with less collimator SCATTER, Maynord F factor method is more accurate to calculate PDD changes with varying SSD. Although, for large depths or SSDs, using the corrected Maynord F factor will show better results for calculating PDD variations with SSD changes.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    CHEGENI, NAHID, TAHMASEBI BIRGANI, MOHAMAD JAVAD, TAHMASBI, MARZIYEH, ZARGANI, ALI, SHABAZIYAN, HOJATOLAH, & ARVANDI, SHOLE. (2017). DETERMINING THE EFFECT OF SOURCE SURFACE DISTANCE VARIATIONS ON PERCENTAGE DEPTH DOSE IN ISOCENTRIC RADIATION THERAPY WITH 6MV PHOTONS. JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL, 16(3 ), 317-326. SID. https://sid.ir/paper/12726/en

    Vancouver: Copy

    CHEGENI NAHID, TAHMASEBI BIRGANI MOHAMAD JAVAD, TAHMASBI MARZIYEH, ZARGANI ALI, SHABAZIYAN HOJATOLAH, ARVANDI SHOLE. DETERMINING THE EFFECT OF SOURCE SURFACE DISTANCE VARIATIONS ON PERCENTAGE DEPTH DOSE IN ISOCENTRIC RADIATION THERAPY WITH 6MV PHOTONS. JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL[Internet]. 2017;16(3 ):317-326. Available from: https://sid.ir/paper/12726/en

    IEEE: Copy

    NAHID CHEGENI, MOHAMAD JAVAD TAHMASEBI BIRGANI, MARZIYEH TAHMASBI, ALI ZARGANI, HOJATOLAH SHABAZIYAN, and SHOLE ARVANDI, “DETERMINING THE EFFECT OF SOURCE SURFACE DISTANCE VARIATIONS ON PERCENTAGE DEPTH DOSE IN ISOCENTRIC RADIATION THERAPY WITH 6MV PHOTONS,” JUNDISHAPUR SCIENTIFIC MEDICAL JOURNAL, vol. 16, no. 3 , pp. 317–326, 2017, [Online]. Available: https://sid.ir/paper/12726/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button