مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,257
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Survey of Accuracy of Arterial CO2 Pressure Estimation From End Tidal CO2 Pressure at Three Exercise Intensities of 30, 50 and 70 Percentage of VO2max

Pages

  183-193

Abstract

 Background & Purpose: The aim of this study was investigation of the effect of Exercise Intensity on accuracy of Arterial CO2 Pressure estimation from End Tidal CO2 Pressure. Methodology: Ten subjects were selected as samples. At first, the maximum oxygen consumption (VO2max) of each subject was obtained by performing progressive exercise protocol. Then, each subject performed three protocols with intensities of 30%, 50% and 70% of his own VO2max and duration of each exercise was 12-minute. Blood samples were taken during the rest, exercise and recovery periods, and data on respiratory gases were collected. Results: Correlation coefficient between PaCO2 and PaCO2pre and P value in exercise with intensities of 30%, 50% and 70% of VO2max were r = 0. 807, P=0. 001; r=0. 822, P= 0. 001 and r = 0. 552, P= 0. 003 respectively. The percentage of estimation error was higher in the intensity of 70% of VO2max than intensities of 30% and 50% of VO2max. Conclusion: Based on the findings of this study, it seems that the accuracy of prediction of Arterial CO2 Pressure from End Tidal CO2 Pressure is lower in high intensities exercise than low intensities exercise.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Afroundeh, Roghayyeh, Irani, Meysam, & shahi, meysam. (2019). Survey of Accuracy of Arterial CO2 Pressure Estimation From End Tidal CO2 Pressure at Three Exercise Intensities of 30, 50 and 70 Percentage of VO2max. JOURNAL OF APPLIED EXERCISE PHYSIOLOGY (JOURNAL OF SPORTS SCIENCE), 15(29 ), 183-193. SID. https://sid.ir/paper/129557/en

    Vancouver: Copy

    Afroundeh Roghayyeh, Irani Meysam, shahi meysam. Survey of Accuracy of Arterial CO2 Pressure Estimation From End Tidal CO2 Pressure at Three Exercise Intensities of 30, 50 and 70 Percentage of VO2max. JOURNAL OF APPLIED EXERCISE PHYSIOLOGY (JOURNAL OF SPORTS SCIENCE)[Internet]. 2019;15(29 ):183-193. Available from: https://sid.ir/paper/129557/en

    IEEE: Copy

    Roghayyeh Afroundeh, Meysam Irani, and meysam shahi, “Survey of Accuracy of Arterial CO2 Pressure Estimation From End Tidal CO2 Pressure at Three Exercise Intensities of 30, 50 and 70 Percentage of VO2max,” JOURNAL OF APPLIED EXERCISE PHYSIOLOGY (JOURNAL OF SPORTS SCIENCE), vol. 15, no. 29 , pp. 183–193, 2019, [Online]. Available: https://sid.ir/paper/129557/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button