مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

762
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

SEISMIC RESPONSE OF COMPOSITE STEEL SHEAR WALLS

Pages

  63-77

Keywords

Not Registered.

Abstract

 Steel composite shear wall system is consisted of steel plates, I shape beams and columns, and composite columns with infill concrete, fc¢. In order to evaluate and improve the behavior of this innovated system, it is necessary to investigate the effect of these parameters on reversed cyclic response. In this paper, a tested steel composite shear wall subjected to cyclic load was modeled. The model was verified using nonlinear dynamic analysis. Several models, in which the effective parameters were varied, have been nonlinear analyzed under dynamic reversed cyclic loads. Results show that by varying these parameters, the general shape of hysteresis loops remained unchanged and the shear behavior with large capability of energy dissipation, were noted. The dissipated energy and dynamic strength increased 10 % to 31% and 20%, respectively, as these parameters changed, where the maximum increase was related to increase of steel plate thickness. Increase of concrete strength to more than 20MPa did not significant effect on ductility, thus using concrete with compressive strength more than 20MPa is not recommended. Based on the results, the ductility ratio of m=7 is determined and recommended.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SHARIATMADAR, H., & ABBASZADEHGAN, M.. (2011). SEISMIC RESPONSE OF COMPOSITE STEEL SHEAR WALLS. STRUCTURE AND STEEL, 7(9), 63-77. SID. https://sid.ir/paper/136634/en

    Vancouver: Copy

    SHARIATMADAR H., ABBASZADEHGAN M.. SEISMIC RESPONSE OF COMPOSITE STEEL SHEAR WALLS. STRUCTURE AND STEEL[Internet]. 2011;7(9):63-77. Available from: https://sid.ir/paper/136634/en

    IEEE: Copy

    H. SHARIATMADAR, and M. ABBASZADEHGAN, “SEISMIC RESPONSE OF COMPOSITE STEEL SHEAR WALLS,” STRUCTURE AND STEEL, vol. 7, no. 9, pp. 63–77, 2011, [Online]. Available: https://sid.ir/paper/136634/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button