مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

782
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Effect of Near-Fault Earthquakes on the Sloshing Behavior of Concrete Rectangular Liquid Storage Tanks

Pages

  401-414

Abstract

 One of the most important components of water supply systems is the Liquid storage tanks. During an earthquake, the interaction of fluid and structure in the Liquid storage tanks and the Sloshing phenomenon has a significant effect on the response values of the structure. Regarding the importance of the effects of near-fault earthquakes and their effect on Seismic behavior and structures loads, in this study, the Sloshing height and vibration of 2D concrete rectangular tanks under near-and far-field earthquakes was investigated using numerical methods. The effect of tank's dimensions, depth of water and ground motion characteristics on the maximum Sloshing height was taken into account. Therefore, 9 tank models and 10 near-and far-field ground motion records were considered. The results indicated that the median values of maximum Sloshing height in the near-field records are significantly higher than those related to far-field records. The average of increase of Sloshing heights in tanks with lengths 20, 40 and 60 meters is 65, 77 and 100 percentage respectively. Also, with increase of fluid depth and tank width, the median of the maximum Sloshing height increases and decreases respectively. In tanks, subjected to far-and near-field earthquakes, Sloshing height had the highest correlation with Arias Intensity and PGV respectively. According to the results of this research, correction coefficients for the relations presented in the codes can be proposed to consider the effects of near-field earthquakes in calculating the maximum Sloshing height.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Mardi Pirsoltan, Mohammad reza, KILANEHEI, FOUAD, & MOHEBI, BENYAMIN. (2019). Effect of Near-Fault Earthquakes on the Sloshing Behavior of Concrete Rectangular Liquid Storage Tanks. AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR), 51(3 ), 401-414. SID. https://sid.ir/paper/165543/en

    Vancouver: Copy

    Mardi Pirsoltan Mohammad reza, KILANEHEI FOUAD, MOHEBI BENYAMIN. Effect of Near-Fault Earthquakes on the Sloshing Behavior of Concrete Rectangular Liquid Storage Tanks. AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR)[Internet]. 2019;51(3 ):401-414. Available from: https://sid.ir/paper/165543/en

    IEEE: Copy

    Mohammad reza Mardi Pirsoltan, FOUAD KILANEHEI, and BENYAMIN MOHEBI, “Effect of Near-Fault Earthquakes on the Sloshing Behavior of Concrete Rectangular Liquid Storage Tanks,” AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR), vol. 51, no. 3 , pp. 401–414, 2019, [Online]. Available: https://sid.ir/paper/165543/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button