مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

476
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Performance Evaluation of Anchored Diaphragm Walls under Service Loads

Pages

  765-780

Abstract

 Nowadays, RC or Combined diaphragm walls are vastly used for deep excavation. This type of retaining structures consists of some piles, which are tied-back using the anchors and anchored from their toe to the ground. Concrete or wood plates were used between them. In order to evaluate the effects of some parameters on wall deflection and its internal forces, several models of combined diaphragm walls were selected and analyzed using FLAC software. Before developing the models, Lim and Braiud (1999) case study was modeled with FLAC2D and results were compared with the experimental results indicating acceptable accuracy of the modeling. The numerical model simulates the soldier piles with beam elements and the anchors with cable elements. The soil model used is a modi? ed hyperbolic model with unloading hysteresis. The complete sequence of construction is simulated including the excavation and the placement and stressing of the anchors. The numerical model is calibrated against an instrumented case history. Then a Parametric Study is conducted. The parameters which is evaluated are: distance and stiffness variation, the bonded and un-bonded length of the anchors, the angle of the anchors and the first raw anchor location. By comparing the different parameters it was observed that the variation of the flexural stiffness of the soldier piles and variation of the bond length of the anchors contain the highest and lowest effect on the maximum horizontal displacement of the wall, respectively. Other analytical results consisting wall deflection vs. geometric characters of the wall are presented and discussed.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    minaei javid, mohsen, RAHAI, ALI REZA, & eslami, abolfazl. (2018). Performance Evaluation of Anchored Diaphragm Walls under Service Loads. AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR), 50(4 ), 765-780. SID. https://sid.ir/paper/165688/en

    Vancouver: Copy

    minaei javid mohsen, RAHAI ALI REZA, eslami abolfazl. Performance Evaluation of Anchored Diaphragm Walls under Service Loads. AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR)[Internet]. 2018;50(4 ):765-780. Available from: https://sid.ir/paper/165688/en

    IEEE: Copy

    mohsen minaei javid, ALI REZA RAHAI, and abolfazl eslami, “Performance Evaluation of Anchored Diaphragm Walls under Service Loads,” AMIRKABIR JOURNAL OF CIVIL ENGINEERING (AMIRKABIR), vol. 50, no. 4 , pp. 765–780, 2018, [Online]. Available: https://sid.ir/paper/165688/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button