مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,872
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE EFFECT OF MODELING METHODS OF MASONRY INFILL ON SEISMIC PERFORMANCE OF RC MOMENT RESISTING FRAMES

Pages

  27-37

Abstract

 In this researches the effect of masonry INFILL in concrete frames behavior have been proceed by two methods: THREE STRUT and diagonal one strut, that THREE STRUT method is known as one of last presented Technique for INFILL masonry modeling so diagonal one strut method is suggested method of retrofit construction for modeling of masonry INFILLs. Three aspects of frames that have been investigated are height (number of story), thickness and modeling method of INFILLs. These frames have been loaded and analyzed based on 519 & 2800 codes. and designed according to ninth discussion of structures public (national) institutes and then analyzed based on nonlinear PUSHOVER ANALYSIS in two state with and without INFILL by sap 2000 software, and the amount of masonries INFILL effect on the frames behavior has been investigated. The results represents that INFILLs increase, strength, stiffness and improve performance level and decrease of hinges number, but in most of analysis states, INFILLs have been destroyed completely and diagonal one strut method in most cases represented conservative results rather than THREE STRUT method for frames. Amount of stiffness increment and drift decrease, because of INFILL presence would be decrease by increase in height. By this, ignorance of INFILLs in lower fames can result in incorrect design and increase of INFILLs thickness did not have such influence on the improve of studied frames behavior in this research.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SALEHI YANESARI, M.M., MORADMAND, H., & SARVGHAD MOGHADAM, A.. (2010). THE EFFECT OF MODELING METHODS OF MASONRY INFILL ON SEISMIC PERFORMANCE OF RC MOMENT RESISTING FRAMES. JOURNAL OF MODELING IN ENGINEERING, 8(20), 27-37. SID. https://sid.ir/paper/173775/en

    Vancouver: Copy

    SALEHI YANESARI M.M., MORADMAND H., SARVGHAD MOGHADAM A.. THE EFFECT OF MODELING METHODS OF MASONRY INFILL ON SEISMIC PERFORMANCE OF RC MOMENT RESISTING FRAMES. JOURNAL OF MODELING IN ENGINEERING[Internet]. 2010;8(20):27-37. Available from: https://sid.ir/paper/173775/en

    IEEE: Copy

    M.M. SALEHI YANESARI, H. MORADMAND, and A. SARVGHAD MOGHADAM, “THE EFFECT OF MODELING METHODS OF MASONRY INFILL ON SEISMIC PERFORMANCE OF RC MOMENT RESISTING FRAMES,” JOURNAL OF MODELING IN ENGINEERING, vol. 8, no. 20, pp. 27–37, 2010, [Online]. Available: https://sid.ir/paper/173775/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button