مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,012
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

PERFORMANCE ANALYSIS OF A TASK/AMBIENT AIR CONDITIONING SYSTEM FOR PROVIDING THE THERMAL COMFORT CONDITIONS DURING SLEEP

Pages

  302-310

Abstract

 In this research, the effects of flow rate and temperature of supply air on the performance of a bed-based TASK/AMBIENT AIR CONDITIONING SYSTEM (TAC) have been investigated. For this reason, a bed-based TASK/AMBIENT AIR CONDITIONING SYSTEM including a bed, a supply air inlet on the top of the occupant's head and a return air outlet under the bed have been considered and for the mentioned conditions, the equations of flow, energy and THERMAL COMFORT have been solved by OpenFoam numerical solver. Also, the THERMAL COMFORT conditions, local thermal discomfort and ENERGY UTILIZATION COEFFICIENT have been evaluated in the present study. The results show that the performance of the mentioned system significantly depends on the supply air temperature and flow rate. So, the low supply air flow rates may cause non-uniform temperature and velocity distributions which leads to unpleasant THERMAL COMFORT conditions. Also, in order to achieve the benefits of TAC systems, utilizing the high supply air flow rates must be avoided because in high flow rates a wide area of the room is affected by supply air instead of the bed zone. Also, the results indicate that the ENERGY UTILIZATION COEFFICIENT decreases with supply air flow rate increment. Therefore, this coefficient has reached to less than 1.5 in 120 lit/s air flow rate that demonstrate the low advantage of using TAC systems in high supply air flow rates.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ZOLFAGHARI, ALIREZA, FOADADDINI, ALI, & HOOSHMAND, MOHAMMAD. (2016). PERFORMANCE ANALYSIS OF A TASK/AMBIENT AIR CONDITIONING SYSTEM FOR PROVIDING THE THERMAL COMFORT CONDITIONS DURING SLEEP. MODARES MECHANICAL ENGINEERING, 15(10), 302-310. SID. https://sid.ir/paper/179624/en

    Vancouver: Copy

    ZOLFAGHARI ALIREZA, FOADADDINI ALI, HOOSHMAND MOHAMMAD. PERFORMANCE ANALYSIS OF A TASK/AMBIENT AIR CONDITIONING SYSTEM FOR PROVIDING THE THERMAL COMFORT CONDITIONS DURING SLEEP. MODARES MECHANICAL ENGINEERING[Internet]. 2016;15(10):302-310. Available from: https://sid.ir/paper/179624/en

    IEEE: Copy

    ALIREZA ZOLFAGHARI, ALI FOADADDINI, and MOHAMMAD HOOSHMAND, “PERFORMANCE ANALYSIS OF A TASK/AMBIENT AIR CONDITIONING SYSTEM FOR PROVIDING THE THERMAL COMFORT CONDITIONS DURING SLEEP,” MODARES MECHANICAL ENGINEERING, vol. 15, no. 10, pp. 302–310, 2016, [Online]. Available: https://sid.ir/paper/179624/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button