مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

525
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

110
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Nonlinear Lining Design Considering Soil-Lining Interaction, Case Study: Gilavand Tunnel

Pages

  3719-3748

Abstract

 There are various methods for the analysis of the interactional behavior of the surrounding land, using the lining structure which is the most common method of deigning lining structure tools for the static loads by using the hyper static methods. In recent years, there has been a question that depicts whether this method provides the best results in designing the tunnel structure or not. Due to the nonlinear behavior of the earth surrounding the lining structure, utilizing the lining method could lead to conservative results in the design. If it is possible to somehow find the forces caused by the real behavior of the land surrounding the lining structure influencing the structure and conduct the design based on them, more optimal results would be obtained. This study is based on the actual behavior of the land surrounding the lining structure and the displacement of the structure caused by forces with linear behavior in the static design according to the non-linear behavior of the land around the tunnel structure. The behavior is modeled using the non-linear programs and the forces affecting the lining of the structure will be inference. Also there is a case study based on this method in which the soil interaction with the tunnel analysis and designing the lining structure was first performed and eventually the obtained results were compared with the hyper static method. In this paper, analysis of maintenance system with lower thicknesses considering land-shield, indicated that applying the reinforced concrete with 40cm thickness has the potential to tolerate the applied load but lining with 45cm thickness is capable of tolerating the loads of design and it can be concluded that applying the simulation method combined with the soil and structure besides considering the nonlinear behavior of the soil leads to more economical results in a project.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    LAVASANI, H.H., & SHARIF TEHRANI, S.. (2017). Nonlinear Lining Design Considering Soil-Lining Interaction, Case Study: Gilavand Tunnel. JOURNAL OF ENGINEERING GEOLOGY, 10(4 ), 3719-3748. SID. https://sid.ir/paper/186317/en

    Vancouver: Copy

    LAVASANI H.H., SHARIF TEHRANI S.. Nonlinear Lining Design Considering Soil-Lining Interaction, Case Study: Gilavand Tunnel. JOURNAL OF ENGINEERING GEOLOGY[Internet]. 2017;10(4 ):3719-3748. Available from: https://sid.ir/paper/186317/en

    IEEE: Copy

    H.H. LAVASANI, and S. SHARIF TEHRANI, “Nonlinear Lining Design Considering Soil-Lining Interaction, Case Study: Gilavand Tunnel,” JOURNAL OF ENGINEERING GEOLOGY, vol. 10, no. 4 , pp. 3719–3748, 2017, [Online]. Available: https://sid.ir/paper/186317/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button