مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

5,768
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF ANALYSIS METHODS OF CHEMICAL OXYGEN DEMAND FOR CONVENTIONAL AND SALINE WASTEWATERS

Pages

  436-442

Keywords

CHEMICAL OXYGEN DEMAND (COD)Q4

Abstract

 Background: In the presence of chloride, bromide and iodide the reported values for Chemical Oxygen Demand (COD) are not real and contain error. The purpose of this study was determining the error in calculating the COD based on Water and Wastewater Standard Testing Methods, in presence of the CHLORIDE ION, in various concentrations of COD.Methods: The experiment was done via two methods: without any removal of the CHLORIDE ION in the first method and using the proposed method of removing the CHLORIDE ION by Water and Wastewater Standard Testing Methods in the second method. In order to remove the impact of the CHLORIDE ION a HgSO4: Cl ratio equal to 10: 1 was used in this method. There were 22 samples that were evaluated twice. NaCl and COD ratios in samples were varied between 1.5-5 g/L and 400-1500 mg/L respectively. Samples divided into two groups, one group without NaCl, the spike sample, and other group unspike sample that had various concentrations of NaCl.Findings: The error value in the first method was 16% and in second method was 10.2%. In the second methods 63.6% of the values were lower than the real values; however in the first method 36.4% of values were lower than the real values that can be due to oxidation of CHLORIDE ION with potassium dichromate (K2Cr2O7).Conclusion: Presence of CHLORIDE ION in SALINE WASTEWATER can lead to an error in determining the COD value. Sometime this error is positive and sometime negative. These errors are greater in high concentration of COD which could be due to CHLORIDE ION oxidation by dichromate and remained some non oxidation organic materials.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    TAHERI, ENSIYEH, HAJIAN NEJAD, MEHDI, AMIN, MOHAMMAD MEHDI, HASANZADEH, AKBAR, & FOROUGHI, MARYAM. (2010). COMPARISON OF ANALYSIS METHODS OF CHEMICAL OXYGEN DEMAND FOR CONVENTIONAL AND SALINE WASTEWATERS. HEALTH SYSTEM RESEARCH, 6(3), 436-442. SID. https://sid.ir/paper/192671/en

    Vancouver: Copy

    TAHERI ENSIYEH, HAJIAN NEJAD MEHDI, AMIN MOHAMMAD MEHDI, HASANZADEH AKBAR, FOROUGHI MARYAM. COMPARISON OF ANALYSIS METHODS OF CHEMICAL OXYGEN DEMAND FOR CONVENTIONAL AND SALINE WASTEWATERS. HEALTH SYSTEM RESEARCH[Internet]. 2010;6(3):436-442. Available from: https://sid.ir/paper/192671/en

    IEEE: Copy

    ENSIYEH TAHERI, MEHDI HAJIAN NEJAD, MOHAMMAD MEHDI AMIN, AKBAR HASANZADEH, and MARYAM FOROUGHI, “COMPARISON OF ANALYSIS METHODS OF CHEMICAL OXYGEN DEMAND FOR CONVENTIONAL AND SALINE WASTEWATERS,” HEALTH SYSTEM RESEARCH, vol. 6, no. 3, pp. 436–442, 2010, [Online]. Available: https://sid.ir/paper/192671/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button