مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

2,599
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CONTROL OF GRID-CONNECTED INVERTER IN STATIONARY REFERENCE FRAME WITH HARMONIC COMPENSATION CAPABILITY

Pages

  57-64

Abstract

 Due to increasing number of inverter based DISTRIBUTED GENERATION RESOURCES in electric power systems, improving the quality and performance of them are necessary. In this paper a new current scheme is presented to inject sinusoidal current to the grid with following grid voltage conditions: sinusoidal voltage, distorted voltage and unbalance voltage. The proposed control scheme includes two sections: 1) Determination of sinusoidal REFERENCE CURRENT considering grid voltage condition; 2) current controller to track REFERENCE CURRENT. The proposed REFERENCE CURRENT determination algorithm in comparison with other algorithms, such as Park method is implemented easier and has faster dynamic response. The proposed current controller is implemented in the stationary reference frame and does not require the use of multiple controllers and coordinate transforms to compensate the harmonics. This control strategy needs tuning of only one variable, hence compared with other control methods requires less computational burden for practical implementation. Simulation results confirm the effectiveness of the proposed control method.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SHAHPARASTI, M., MOHAMADIAN, M., & YAZDIAN, A.. (2015). CONTROL OF GRID-CONNECTED INVERTER IN STATIONARY REFERENCE FRAME WITH HARMONIC COMPENSATION CAPABILITY. NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ, 13(1), 57-64. SID. https://sid.ir/paper/228142/en

    Vancouver: Copy

    SHAHPARASTI M., MOHAMADIAN M., YAZDIAN A.. CONTROL OF GRID-CONNECTED INVERTER IN STATIONARY REFERENCE FRAME WITH HARMONIC COMPENSATION CAPABILITY. NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ[Internet]. 2015;13(1):57-64. Available from: https://sid.ir/paper/228142/en

    IEEE: Copy

    M. SHAHPARASTI, M. MOHAMADIAN, and A. YAZDIAN, “CONTROL OF GRID-CONNECTED INVERTER IN STATIONARY REFERENCE FRAME WITH HARMONIC COMPENSATION CAPABILITY,” NASHRIYYAH -I MUHANDISI -I BARQ VA MUHANDISI -I KAMPYUTAR -I IRAN, A- MUHANDISI -I BARQ, vol. 13, no. 1, pp. 57–64, 2015, [Online]. Available: https://sid.ir/paper/228142/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button