مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,003
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

AN EXPERIMENTAL INVESTIGATION OF THE PARAMETERS INVOLVED IN DETERMINATION OF THE TRANSIENT RESPONSE OF A RESISTIVE GAS SENSOR

Pages

  69-79

Abstract

 Gas sensitive metal oxide layers used in fabrication of resistive GAS SENSORs are prepared by different deposition techniques. The technical data reported on some basic and practically important specifications of these devices, although fabricated based on the same gas sensitive oxide, are anomalously different. The influence of the FABRICATION TECHNIQUE used for the deposition of the gas sensitive layer on determination of the significant specifications of the TRANSIENT RESPONSE of a resistive GAS SENSOR is experimentally investigated for the first time. ZnO and SnO2 layers were prepared by LPCVD, PVD, EPD and powder pressing techniques. Prototype GAS SENSORs based on these layers were fabricated. The TRANSIENT RESPONSEs of these devices to a step change in the composition of the surrounding atmosphere were recorded and compared. It was shown that the thickness, porosity and pore micro-structure of the gas sensitive layer are the most effective parameters in determination of the TRANSIENT RESPONSE. The relationship between these parameters and the temporal variation of the electrical conductivity of the gas sensitive layer was qualitatively analyzed. Oxide layers of higher porosity resulted in GAS SENSORs of faster response, but RESPONSE TIME increased with the thickness of these gas sensitive layers. The sensors produced by EPD technique demonstrated the fastest responses while those produced by CVD were the slowest among the samples investigated.    

Cites

References

Cite

APA: Copy

ORVATINIA, M., & HOSSEIN BABAEI, F.. (2006). AN EXPERIMENTAL INVESTIGATION OF THE PARAMETERS INVOLVED IN DETERMINATION OF THE TRANSIENT RESPONSE OF A RESISTIVE GAS SENSOR. MODARES TECHNICAL AND ENGINEERING, -(22), 69-79. SID. https://sid.ir/paper/25100/en

Vancouver: Copy

ORVATINIA M., HOSSEIN BABAEI F.. AN EXPERIMENTAL INVESTIGATION OF THE PARAMETERS INVOLVED IN DETERMINATION OF THE TRANSIENT RESPONSE OF A RESISTIVE GAS SENSOR. MODARES TECHNICAL AND ENGINEERING[Internet]. 2006;-(22):69-79. Available from: https://sid.ir/paper/25100/en

IEEE: Copy

M. ORVATINIA, and F. HOSSEIN BABAEI, “AN EXPERIMENTAL INVESTIGATION OF THE PARAMETERS INVOLVED IN DETERMINATION OF THE TRANSIENT RESPONSE OF A RESISTIVE GAS SENSOR,” MODARES TECHNICAL AND ENGINEERING, vol. -, no. 22, pp. 69–79, 2006, [Online]. Available: https://sid.ir/paper/25100/en

Related Journal Papers

Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button