مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,302
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EFFECT OF THERMAL CHANGES ON TOOTH RESPONSE TO THE ELECTRIC PULP TESTER

Pages

  273-276

Abstract

 Background and Aims: The vitality PULP TESTs are necessary for diagnosis of pulpal disease and differentiation between endodontic and non-endodontic diseases. Thermal and electrical tests are conventional methods for evaluation of PULP VITALITY. The purpose of this study was to evaluate the effect of thermal changes on the tooth RESPONSE to the electric PULP TESTer.Materials and Methods: In this study, 160 intact maxillary central incisors of 40 voluntaries were evaluated.After isolation, electric pulpal RESPONSE threshold in patients were recorded. After heat and cold tests, the electrical PULP TEST was repeated. The degree of RESPONSE was recorded. The data were analyzed using pair T-test and independent T-test.Results: The result of this study demonstrated that the average of teeth RESPONSE to the electric PULP TESTer before and after cold test was 1.3 and 1.7, respectively. The average was 1.4 and 1.7 before and after heat test, respectively. There was no significant difference (P<0.001) between the pulpal RESPONSE before and after thermal tests (heat and cold tests). In addition, no significant difference was found between pulpal RESPONSE after heat and cold tests (P=0.25).Conclusion: The RESPONSE of tooth to the electric PULP TESTer was influenced by heat and cold tests.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MODARESI, JALIL, MOKHTARI, FATEMEH, KHALIL SEFAT, YOUSEF, & SHAHNAZIAN, HOSSEIN. (2013). EFFECT OF THERMAL CHANGES ON TOOTH RESPONSE TO THE ELECTRIC PULP TESTER. JOURNAL OF DENTAL MEDICINE, 25(4 (73)), 273-276. SID. https://sid.ir/paper/25235/en

    Vancouver: Copy

    MODARESI JALIL, MOKHTARI FATEMEH, KHALIL SEFAT YOUSEF, SHAHNAZIAN HOSSEIN. EFFECT OF THERMAL CHANGES ON TOOTH RESPONSE TO THE ELECTRIC PULP TESTER. JOURNAL OF DENTAL MEDICINE[Internet]. 2013;25(4 (73)):273-276. Available from: https://sid.ir/paper/25235/en

    IEEE: Copy

    JALIL MODARESI, FATEMEH MOKHTARI, YOUSEF KHALIL SEFAT, and HOSSEIN SHAHNAZIAN, “EFFECT OF THERMAL CHANGES ON TOOTH RESPONSE TO THE ELECTRIC PULP TESTER,” JOURNAL OF DENTAL MEDICINE, vol. 25, no. 4 (73), pp. 273–276, 2013, [Online]. Available: https://sid.ir/paper/25235/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button