مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,854
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

FINITE ELEMENT ANALYSIS FOR DENTAL IMPLANTS SUBJECTED TO THERMAL LOADS

Pages

  270-280

Abstract

 Background and Aims: DENTAL IMPLANTS have been studied for replacement of missing teeth for many years. Productivity of implants is extremely related to the stability and resistance under applied loads and the minimum stress in jaw bone. The purpose of this study was to study numerically the 3D model of implant under thermal loads.Materials and Methods: Bone and the ITI implant were modeled in “Solidworks” software. To obtain the exact model, the bone was assumed as a linear orthotropic material. The implant system, including implant, abutment, framework and crown were modeled and located in the bone. After importing the model in Abaqus software, the material properties and boundary conditions and loads were applied and after meshing, the model was analyzed. In this analysis, the loads were applied in two steps. In the first step, the mechanical load was applied as tightening torque to the abutment and the abutment was tightened in the implant with 35 N.cm torque. In the second step, the thermal load originated from drinking cold and hot water was applied as thermal flux on the ceramic crown surface in this model.Results: THERMAL ANALYSIS results showed that the thermal gradient in the bone was about 5.5 and 4.9 degrees of centigrade in the case of drinking cold and hot water respectively, although the maximum gradient of the whole system was reduced to 14 degrees, which occurred, in the crown by drinking cold water.Conclusion: THERMAL STRESSes were so small and it was because of the low thermal gradient. Maximum stresses occurred in the abutment were due to the tension preloads which were originated from the tightening torque.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KHALILI, MOHAMMAD REZA, ZIAIE, BABAK, & KAZEMI, MAHMOUD. (2014). FINITE ELEMENT ANALYSIS FOR DENTAL IMPLANTS SUBJECTED TO THERMAL LOADS. JOURNAL OF DENTAL MEDICINE, 26(4 (77)), 270-280. SID. https://sid.ir/paper/25508/en

    Vancouver: Copy

    KHALILI MOHAMMAD REZA, ZIAIE BABAK, KAZEMI MAHMOUD. FINITE ELEMENT ANALYSIS FOR DENTAL IMPLANTS SUBJECTED TO THERMAL LOADS. JOURNAL OF DENTAL MEDICINE[Internet]. 2014;26(4 (77)):270-280. Available from: https://sid.ir/paper/25508/en

    IEEE: Copy

    MOHAMMAD REZA KHALILI, BABAK ZIAIE, and MAHMOUD KAZEMI, “FINITE ELEMENT ANALYSIS FOR DENTAL IMPLANTS SUBJECTED TO THERMAL LOADS,” JOURNAL OF DENTAL MEDICINE, vol. 26, no. 4 (77), pp. 270–280, 2014, [Online]. Available: https://sid.ir/paper/25508/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button