مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

355
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

121
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

3D MRI GEL DOSIMETRY BASED ON IMAGE INTENSITY (A NEW APPROACH)

Pages

  45-50

Abstract

 Background: Since 1984 MRI GEL DOSIMETRY has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied IMAGE INTENSITY change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% by weight agarose in distilled water. Prepared gels were poured in Plastic tube phantom and irradiated to a beam of Co-60 gamma rays. Imaging was performed by a 0.5T MRI system in the head coil with SE and GRE techniques.Results: Our results showed that linear response exists between the variations of IMAGE INTENSITY with absorbed dose (1-15 Gy). Optimal imaging parameters should be defined locally according to the type of MRI scanner and exact composition of the gel. Gradient echo (GRE) imaging technique also have been studied in comparison with classic spin echo (SE) imaging technique which will be discussed in detail. Conclusions: Linearity of absorbed dose with intensity exists up to 15 Gy and can be used for MRI GEL DOSIMETRY. Reduction of imaging time is achievable in IMAGE INTENSITY technique so that it’s possible to image the gel in less than 20 minutes, which is critical to over-come the adverse ion-diffusion properties of the Fricke gel. Iran

Cites

References

  • No record.
  • Cite

    APA: Copy

    AKHLAGHPOUR, SH., ZAHMATKESH, M.H., & POURBEYGI, H.. (2003). 3D MRI GEL DOSIMETRY BASED ON IMAGE INTENSITY (A NEW APPROACH). INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 1(1), 45-50. SID. https://sid.ir/paper/286276/en

    Vancouver: Copy

    AKHLAGHPOUR SH., ZAHMATKESH M.H., POURBEYGI H.. 3D MRI GEL DOSIMETRY BASED ON IMAGE INTENSITY (A NEW APPROACH). INTERNATIONAL JOURNAL OF RADIATION RESEARCH[Internet]. 2003;1(1):45-50. Available from: https://sid.ir/paper/286276/en

    IEEE: Copy

    SH. AKHLAGHPOUR, M.H. ZAHMATKESH, and H. POURBEYGI, “3D MRI GEL DOSIMETRY BASED ON IMAGE INTENSITY (A NEW APPROACH),” INTERNATIONAL JOURNAL OF RADIATION RESEARCH, vol. 1, no. 1, pp. 45–50, 2003, [Online]. Available: https://sid.ir/paper/286276/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button