مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

152
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

104
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study

Pages

  106-115

Abstract

 Objectives: The retentive properties of implant-retained Overdentures (IRO) may be influenced by the type of attachments. The aim of this research was to compare the retention of two dental implant systems with compatible ball attachments, namely Straumann® system (SS) and Rhein83 SRL system (RS) after fatigue testing. Materials and Methods: Two laboratory models consisting of two parallel Straumann® fixtures at a distance of 22 mm were prepared. Five pairs of each systems' ball attachments were examined (n=5). The samples were soaked in artificial saliva. The retention strength values (RSV) were recorded before the fatigue test and after 1100, 2200, 3300, 4400, and 5500 insertion and removal cycles at a speed of 51 mm/minute with a 50-N load cell in a universal testing machine. The data were analyzed by repeated measures analysis of variance (ANOVA) followed by independent sample t-test with Bonferroni corrections. Results: There was a decrease in the RSV in both systems after 5500 cycles of insertion and removal. There was a significant statistical difference between the RSV of the normal Sphero Block of the RS (17. 52± 0. 68 N) and that of the Spare Lamella retention inserts of the SS (19. 72± 0. 74 N, P=0. 001). Conclusions: Although the RSVs of the RS and SS were almost similar before the fatigue test, as the number of insertion and removal cycles increased, the RSV decreased more significantly in the RS compared to the SS.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Memarian, maryam, ZARRATI, SIMINDOKHT, KARIMI, SEDIGHEH, & BAHRAMI, MEHRAN. (2018). Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study. FRONTIERS IN DENTISTRY (JOURNAL OF DENTISTRY OF TEHRAN UNIVERSITY OF MEDICAL SCIENCES), 15(2), 106-115. SID. https://sid.ir/paper/298140/en

    Vancouver: Copy

    Memarian maryam, ZARRATI SIMINDOKHT, KARIMI SEDIGHEH, BAHRAMI MEHRAN. Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study. FRONTIERS IN DENTISTRY (JOURNAL OF DENTISTRY OF TEHRAN UNIVERSITY OF MEDICAL SCIENCES)[Internet]. 2018;15(2):106-115. Available from: https://sid.ir/paper/298140/en

    IEEE: Copy

    maryam Memarian, SIMINDOKHT ZARRATI, SEDIGHEH KARIMI, and MEHRAN BAHRAMI, “Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study,” FRONTIERS IN DENTISTRY (JOURNAL OF DENTISTRY OF TEHRAN UNIVERSITY OF MEDICAL SCIENCES), vol. 15, no. 2, pp. 106–115, 2018, [Online]. Available: https://sid.ir/paper/298140/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button