Title

Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty

Pages

  18-26

Abstract

 Purpose: To evaluate the effects of Donor Graft Thickness on postoperative best spectacle‑ corrected visual acuity (BSCVA), refractive outcomes, endothelial cell density (ECD) and function, intraocular pressure (IOP), and postoperative complications after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK). Methods: This retrospective, interventional case series enrolled 77 eyes of 64 patients who underwent DSAEK with or without simultaneous cataract surgery. Clinical Outcomes, including BSCVA, refraction, keratometric astigmatism, IOP, and ECD were assessed at the final follow‑ up examination. Univariate analyses were used to investigate the effects of postoperative Donor Graft Thickness on Clinical Outcomes and complications. Results: The mean patient age was 62. 3 ± 15. 6 years, and the patients were followed for 26. 2 ± 20. 9 months postoperatively. The mean postoperative central graft thickness was 102. 4 ± 31. 6 µ m. In the univariate analysis, postoperative central graft thickness was significantly associated with postoperative IOP (P = 0. 005), central recipient thickness (P = 0. 002), and ECD (P = 0. 016). No significant association was found for central graft thickness with postoperative BSCVA (P = 0. 70), spherical equivalent refraction (P = 0. 33), keratometric astigmatism (P = 0. 27), graft detachment (P = 0. 16), graft decentration (P = 0. 17), high IOP (P = 0. 53), or endothelial rejection (P = 0. 88). Conclusion: This study failed to demonstrate any significant correlation between graft thickness and BSCVA. Attempting to minimize graft thickness might not have the desired outcome regarding endothelial cell density and function. Increased graft thickness could negatively impact the accuracy of IOP measurements after DSAEK.

Cites

References

  • No record.
  • Cite

    APA: Copy

    FEIZI, SEPEHR, & JAVADI, MOHAMMAD ALI. (2019). Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty. JOURNAL OF OPHTHALMIC AND VISION RESEARCH, 14(1), 18-26. SID. https://sid.ir/paper/311755/en

    Vancouver: Copy

    FEIZI SEPEHR, JAVADI MOHAMMAD ALI. Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty. JOURNAL OF OPHTHALMIC AND VISION RESEARCH[Internet]. 2019;14(1):18-26. Available from: https://sid.ir/paper/311755/en

    IEEE: Copy

    SEPEHR FEIZI, and MOHAMMAD ALI JAVADI, “Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty,” JOURNAL OF OPHTHALMIC AND VISION RESEARCH, vol. 14, no. 1, pp. 18–26, 2019, [Online]. Available: https://sid.ir/paper/311755/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button