مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

2,852
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

SENSITIVE CHEMILUMINESCENCE METHOD FOR SUPEROXIDE DISMUTASE ACTIVITY ASSAY

Pages

  129-133

Abstract

 Aims: Measuring SUPEROXIDE DISMUTASE activity is of importance in common diseases like cardiovascular disease, cancer and autoimmune disorders. Nowadays measuring enzyme activity is performed with expensive imported kits in different fields of science. The aim of this study was to design a quantitative method for chemiluminometeric measurement of SUPEROXIDE DISMUTASE activity with improved sensitivity, accuracy and speed.Materials & Methods: In this method luminol substrate and iodophenol were used as reaction accelerators in luminometry measuring reaction in order to determine the SUPEROXIDE DISMUTASE activity in serum samples and to increase measurement sensitivity. Sensitivity, precision tests, intra and inter-assay test, accuracy tests, recovery and parallelism tests, method comparison and methods’ correlation and coherence investigation were also performed. In order to increase reading speed and precision, measurement was performed in microplate and reading was done in luminometry plate.Results: Standard operating range was 3 to 300 U/ml. Sensitivity of the method was 0.1U/ml. Intra and interassay coefficient of variation was less than 6.6 and 7.3% respectively. In recovery and Parallelism tests, the recovery percent range was 92 to 110. Comparison of common colorimetric method and the designed method indicated a Pearson's correlation coefficient of 0.917.Conclusion: This method can measure SUPEROXIDE DISMUTASE activity in serum samples with acceptable precision and accuracy and probably can be a good alternative for conventional colorimetric methods.

Cites

  • No record.
  • References

    Cite

    APA: Copy

    DEHBASHI BEHBAHANI, G., HAJHOSSEINI, R., HOGHOUGHIRAD, L., & HEDAYATI, MAHDI. (2010). SENSITIVE CHEMILUMINESCENCE METHOD FOR SUPEROXIDE DISMUTASE ACTIVITY ASSAY. KOWSAR MEDICAL JOURNAL, 15(3), 129-133. SID. https://sid.ir/paper/32744/en

    Vancouver: Copy

    DEHBASHI BEHBAHANI G., HAJHOSSEINI R., HOGHOUGHIRAD L., HEDAYATI MAHDI. SENSITIVE CHEMILUMINESCENCE METHOD FOR SUPEROXIDE DISMUTASE ACTIVITY ASSAY. KOWSAR MEDICAL JOURNAL[Internet]. 2010;15(3):129-133. Available from: https://sid.ir/paper/32744/en

    IEEE: Copy

    G. DEHBASHI BEHBAHANI, R. HAJHOSSEINI, L. HOGHOUGHIRAD, and MAHDI HEDAYATI, “SENSITIVE CHEMILUMINESCENCE METHOD FOR SUPEROXIDE DISMUTASE ACTIVITY ASSAY,” KOWSAR MEDICAL JOURNAL, vol. 15, no. 3, pp. 129–133, 2010, [Online]. Available: https://sid.ir/paper/32744/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button