مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

38
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

11
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

SURGICAL MANAGEMENT OF TIBIAL PLATEAU FRACTURES WITH 3.5MMSIMPLE PLATES

Pages

  0-0

Abstract

 Background: TIBIAL PLATEAU FRACTUREs can be successfully fixed utilizing 3.5mmlocking plates. However, there are some disadvantages to using these plates.Objectives: In the current prospective study, we investigated the outcome of treating different types of TIBIAL PLATEAU FRACTUREs with 3.5mmsimple plates which, to our knowledge, has not been evaluated in previous studies.Materials and Methods: Between 2011 and 2013, 32 patients aged 40  0.2 years underwent open reduction and INTERNAL FIXATION for TIBIAL PLATEAU FRACTUREs with 3.5mmsimple plates. The patients were followed for 16.142.1 months. At each patient’s final visit, the articular surface depression, medial proximal tibial angle, and slope angle were measured and compared with measurements taken early after the operation. The functional outcomes were measured with the WOMAC and Lysholm knee scores.Results: The mean union time was 131.2 weeks. The mean knee range of motion was 116.8°3.3°. The mean WOMACand Lysholm scores were 83.51.8 and 76.81.6, respectively. On the early postoperative and final X-rays, 87.5% and 84% of patients, respectively, had acceptable reduction. Medial proximal tibial and slope angles did not change significantly by the last visit. No patient was found to have complications related to the type of plate.Conclusions: In this case series study, the fixation of different types of TIBIAL PLATEAU FRACTUREs with 3.5mmsimple non-locking and non-precontoured plates was associated with acceptable clinical, functional, and radiographic outcomes. Based on the advantages and costs of these plates, the authors recommend using 3.5mmsimple plates for different types of TIBIAL PLATEAU FRACTUREs.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BAGHERIFARD, ABOLFAZL, JABALAMELI, MAHMOUD, HADI, HOSSEINALI, RAHBAR, MOHAMMAD, MINATOR SAJJADI, MOHAMMADREZA, JAHANSOUZ, ALI, & KARIMI HERIS, HOSSEIN. (). . , (), -. SID. https://sid.ir/paper/334161/en

    Vancouver: Copy

    BAGHERIFARD ABOLFAZL, JABALAMELI MAHMOUD, HADI HOSSEINALI, RAHBAR MOHAMMAD, MINATOR SAJJADI MOHAMMADREZA, JAHANSOUZ ALI, KARIMI HERIS HOSSEIN. . [Internet]. ;():-. Available from: https://sid.ir/paper/334161/en

    IEEE: Copy

    ABOLFAZL BAGHERIFARD, MAHMOUD JABALAMELI, HOSSEINALI HADI, MOHAMMAD RAHBAR, MOHAMMADREZA MINATOR SAJJADI, ALI JAHANSOUZ, and HOSSEIN KARIMI HERIS, “,” , vol. , no. , pp. –, , [Online]. Available: https://sid.ir/paper/334161/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button