مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

203
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

82
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

Breast Conservation From Radiation Damage by Using Nano Bismuth Shields in Chest Computed Tomography Scan

Pages

  46-50

Abstract

 Objectives: The present study aimed to calculate the efficiency of bismuth nanoparticles shield to protect the breast in chest computed tomography (CT) scan and investigate the alteration of Image quality after using the shield. Materials and Methods: Three groups were included in this experimental research in which phantom was scanned without using Nano bismuth shield (group 1), using 0. 5 mm Nano bismuth shield (group 2), and employing Nano bismuth shield with 1 mm thickness (group 3). The polymethyl methacrylate phantom was applied to present the main organ of the chest including the breast and lung. Multi-detector 6-slice CT scan system was utilized for the tests. In addition, the breast radiation dose was measured by ion-chamber which was placed at 12 o’ clock position in the phantom according to dosimetry protocol. Further, Chest CT image processing was performed once without shield and once in the presence of 10% Nano bismuth shield with different thicknesses. Finally, Image quality was compared by adding the shield for correct diagnosis. Tests were repeated three time and data were analyzed by ANOVA. Results: Based on the results, using Nano bismuth Shields, breast dose reduced by 7. 2% and 13. 8% for 0. 5 and 1 mm thickness of the shield, respectively. Furthermore, the CT number and noise increased from 121. 3 to 126. 36 HU and from 24. 53 to 28. 1 HU, respectively. Finally, the Dose reduction ratio approximately doubled by increasing the thickness from 0. 5 to 1 mm. Conclusions: Generally, Nano bismuth Shields have a noticeable potential for reducing the breast dose with the smallest change in the noise.

Cites

References

Cite

APA: Copy

Mehnati, Parinaz, Yousefi Sooteh, Mohammad, MALEKZADEH, REZA, Divband, Baharak, & REFAHI, SOHEILA. (2019). Breast Conservation From Radiation Damage by Using Nano Bismuth Shields in Chest Computed Tomography Scan. CRESCENT JOURNAL OF MEDICAL AND BIOLOGICAL SCIENCES, 6(1), 46-50. SID. https://sid.ir/paper/345025/en

Vancouver: Copy

Mehnati Parinaz, Yousefi Sooteh Mohammad, MALEKZADEH REZA, Divband Baharak, REFAHI SOHEILA. Breast Conservation From Radiation Damage by Using Nano Bismuth Shields in Chest Computed Tomography Scan. CRESCENT JOURNAL OF MEDICAL AND BIOLOGICAL SCIENCES[Internet]. 2019;6(1):46-50. Available from: https://sid.ir/paper/345025/en

IEEE: Copy

Parinaz Mehnati, Mohammad Yousefi Sooteh, REZA MALEKZADEH, Baharak Divband, and SOHEILA REFAHI, “Breast Conservation From Radiation Damage by Using Nano Bismuth Shields in Chest Computed Tomography Scan,” CRESCENT JOURNAL OF MEDICAL AND BIOLOGICAL SCIENCES, vol. 6, no. 1, pp. 46–50, 2019, [Online]. Available: https://sid.ir/paper/345025/en

Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button