مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

14,036
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF SERUM BILIRUBIN MEASUREMENT IN LABORATORY AND TRANSCUTANEOUS BILIRUBINOMETRY

Pages

  151-154

Abstract

 Background and Purpose: Bili-Check is a simple method used to provide a rapid pain-free and noninvasive transcutaneous estimation of total serum bilirubin. The present study was conducted to compare estimates of serum bilirubin using Bili-Check (TCB) with total serum bilirubin (TSB) values determined in a clinical laboratory. Methods and Materials: This is a dehlive analytical cross-sectional study conducted in Ghaem Hospital NICU from September 2008 to March 2008. With a confidence interval of 95% and test power of 80% 109 NEONATEs were selected through convenient non-randomized sampling as the study sample. TSB was determined in a clinical laboratory using the diazo with photometric method. Then within 10 minutes transcutaneous measurements were performed via Bili-Check. Data analysis was done in SPSS11.5 using correlation coefficient. Results: From 109 NEONATEs included in the study 75 were male (68.8%) and 34 female (31.2%) with an age range of 1 to 26 days. Mean serum Bilirubin was 12.979 and TCB estimate was 12.219. Laboratory findings highly correlated with the results of TCB (r=0.766) (P=0.0001). Conclusion: Bili-Check has the sufficient adequacy as the measurement and observation device for NEONATEs and can replace serum bilirubinometry in laboratory fro ICTERic NEONATEs.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SAEIDI, R., GHOLAMI ROBATSANGI, M., MIRZA RAHIMI, M., & AMIRI TEHRANI ZADEH, M.. (2009). COMPARISON OF SERUM BILIRUBIN MEASUREMENT IN LABORATORY AND TRANSCUTANEOUS BILIRUBINOMETRY. JOURNAL OF SABZEVAR UNIVERSITY OF MEDICAL SCIENCES, 16(3 (53)), 151-154. SID. https://sid.ir/paper/356779/en

    Vancouver: Copy

    SAEIDI R., GHOLAMI ROBATSANGI M., MIRZA RAHIMI M., AMIRI TEHRANI ZADEH M.. COMPARISON OF SERUM BILIRUBIN MEASUREMENT IN LABORATORY AND TRANSCUTANEOUS BILIRUBINOMETRY. JOURNAL OF SABZEVAR UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2009;16(3 (53)):151-154. Available from: https://sid.ir/paper/356779/en

    IEEE: Copy

    R. SAEIDI, M. GHOLAMI ROBATSANGI, M. MIRZA RAHIMI, and M. AMIRI TEHRANI ZADEH, “COMPARISON OF SERUM BILIRUBIN MEASUREMENT IN LABORATORY AND TRANSCUTANEOUS BILIRUBINOMETRY,” JOURNAL OF SABZEVAR UNIVERSITY OF MEDICAL SCIENCES, vol. 16, no. 3 (53), pp. 151–154, 2009, [Online]. Available: https://sid.ir/paper/356779/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button