Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

824
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

1

Information Journal Paper

Title

EXTRACTION OF DIAGNOSTIC PARAMETERS FROM THE TRANSIENT RESPONSE OF A POROUS ELECTROCERAMIC GAS SENSOR

Pages

  349-359

Keywords

Not Registered.

Abstract

 A novel concept for the diagnosis of a pure target gas (TG) in air is presented. The method employs a resistive gas sensor with a mm-thick highly porous electro ceramic gas-sensitive body. The diagnosis is based on the fact that the diffusion time of the TG through the porous body would depend on its molecular properties. The transient response of the device was analyzed based on a diffusion-reaction equation. The solutions of the equation were defined by three parameters, which were shown to be of diagnostic merits. Such a device was fabricated by partial sintering of a ZnO body formed by low-pressure pressing. The transient responses of the device to methanol, ethanol, poropanol and butanol were recorded. The analytical solutions were fitted to the experimental data, and the diagnostic parameters were resulted as the fitting parameters. Comparison of the parameters obtained with those available from the calibration experiments afforded TG identification.

Cites

References

  • No record.
  • Cite

    APA: Copy

    HOSSEIN BABAEI, F., & ORVATINIA, M.. (2004). EXTRACTION OF DIAGNOSTIC PARAMETERS FROM THE TRANSIENT RESPONSE OF A POROUS ELECTROCERAMIC GAS SENSOR. JOURNAL OF FACULTY OF ENGINEERING (UNIVERSITY OF TEHRAN), 38(3 (85)), 349-359. SID. https://sid.ir/paper/357956/en

    Vancouver: Copy

    HOSSEIN BABAEI F., ORVATINIA M.. EXTRACTION OF DIAGNOSTIC PARAMETERS FROM THE TRANSIENT RESPONSE OF A POROUS ELECTROCERAMIC GAS SENSOR. JOURNAL OF FACULTY OF ENGINEERING (UNIVERSITY OF TEHRAN)[Internet]. 2004;38(3 (85)):349-359. Available from: https://sid.ir/paper/357956/en

    IEEE: Copy

    F. HOSSEIN BABAEI, and M. ORVATINIA, “EXTRACTION OF DIAGNOSTIC PARAMETERS FROM THE TRANSIENT RESPONSE OF A POROUS ELECTROCERAMIC GAS SENSOR,” JOURNAL OF FACULTY OF ENGINEERING (UNIVERSITY OF TEHRAN), vol. 38, no. 3 (85), pp. 349–359, 2004, [Online]. Available: https://sid.ir/paper/357956/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top