مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

547
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Determining the Fetal Dose in Ventilation/Perfusion Scan Using Monte Carlo Simulation

Pages

  237-241

Abstract

 Background: Pulmonary embolism (PE) is a blockage in one of the pulmonary arteries. Ventilation/Perfusion (V/Q) scan is one the diagnostic methods of PE in pregnant women. It is necessary to investigate fetal dose and compare it with recommended values. The aim of this study was to determine the fetal dose in V/Q scan using Monte Carlo simulation. Methods: An adult pregnant woman phantom and all her displaced organs were used for simulation. Source organs were defined for each of the radiopharmaceuticals used in two lung ventilation and perfusion scans, including lung and bladder for 133Xe, 81mKr, and technetium diethylene-triamine-pentaacetate aerosol (99mTc-DTPA-aerosol) for lung ventilation scan, and lung, bladder, and liver for 99mTc-technetium macroaggregated albumin (MAA) for lung perfusion scan. Fetal dose was determined and evaluated using the simulation output after calculations. Findings: For 99mTc-MAA at prescription dose of 200 MBq, fetal dose was found to be 1. 01 mGy, maximum fetal dose was 1. 97 mGy, and both of them were more than the values recommended by International Commission on Radiological Protection (ICRP). For 99mTc-DTPA, fetal and maximum doses were below 1 mGy, and for 133Xe and 81mKr, fetal dose was negligible. Conclusion: It is concluded that considering higher dose to the Fetus (200 MBq of 99mTc-MAA), if the pregnant woman scan is needed, her awareness must be done.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Vakili, Shahabeddin, & SHAHBAZI GAHROUEI, DARYOUSH. (2019). Determining the Fetal Dose in Ventilation/Perfusion Scan Using Monte Carlo Simulation. JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), 37(519 ), 237-241. SID. https://sid.ir/paper/363782/en

    Vancouver: Copy

    Vakili Shahabeddin, SHAHBAZI GAHROUEI DARYOUSH. Determining the Fetal Dose in Ventilation/Perfusion Scan Using Monte Carlo Simulation. JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S)[Internet]. 2019;37(519 ):237-241. Available from: https://sid.ir/paper/363782/en

    IEEE: Copy

    Shahabeddin Vakili, and DARYOUSH SHAHBAZI GAHROUEI, “Determining the Fetal Dose in Ventilation/Perfusion Scan Using Monte Carlo Simulation,” JOURNAL OF ISFAHAN MEDICAL SCHOOL (I.U.M.S), vol. 37, no. 519 , pp. 237–241, 2019, [Online]. Available: https://sid.ir/paper/363782/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button