مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

789
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Evaluation of the Efficiency of Hybrid Dry Cooling Tower by Placing the Air Cooling Condenser inside the Heller Cooling Tower

Pages

  441-452

Keywords

Natural Draft Dry Cooling Towers (Heller)Q1

Abstract

 The Heller towers are the most common types of power plants cooling towers, where their efficiency is very sensitive to wind. According to the general approach of cooling systems designer, Direct dry cooling (ACC) systems are more popular today in power plants located in arid areas. In Heller towers due to the empty space inside them, in this study, instead of proposing the replacement of ACC towers, the Hybrid Model is proposed, where steam is Directly passed into the ACC radiators without fan installed inside the Heller Tower, and condenses with a natural suction mechanism. The flow around the proposed model is investigated in three dimensions in two cases of no wind and at 8 different wind speeds with the assumption of incompressibility flow by the continuity, momentum, energy, and turbulence equations. The hybrid tower performance has been compared with the Fars power plant cooling system and it has been shown that the proposed cooling tower has performed 25% better than the Fars cooling system in no wind condition. It has also performed better in wind conditions at different speeds except for speeds above 12. 5 m/s at a parallel and vertical array with the wind of ACCs. A vertical array of ACCs performance has been better than the parallel array. Therefore, the Hybrid Model with a vertical array of ACCs can be efficient to replace the cooling system of the Fars power plant.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Gharebaei, H., JAHANGIRI, A., & AMERI, M.. (2021). Evaluation of the Efficiency of Hybrid Dry Cooling Tower by Placing the Air Cooling Condenser inside the Heller Cooling Tower. MODARES MECHANICAL ENGINEERING, 21(7 ), 441-452. SID. https://sid.ir/paper/369679/en

    Vancouver: Copy

    Gharebaei H., JAHANGIRI A., AMERI M.. Evaluation of the Efficiency of Hybrid Dry Cooling Tower by Placing the Air Cooling Condenser inside the Heller Cooling Tower. MODARES MECHANICAL ENGINEERING[Internet]. 2021;21(7 ):441-452. Available from: https://sid.ir/paper/369679/en

    IEEE: Copy

    H. Gharebaei, A. JAHANGIRI, and M. AMERI, “Evaluation of the Efficiency of Hybrid Dry Cooling Tower by Placing the Air Cooling Condenser inside the Heller Cooling Tower,” MODARES MECHANICAL ENGINEERING, vol. 21, no. 7 , pp. 441–452, 2021, [Online]. Available: https://sid.ir/paper/369679/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button