Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

890
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EVALUATION OF BASIC PARAMETERS OF REAL-TIME DIAGNOSTIC ULTRASOUND SYSTEMS

Pages

  73-80

Abstract

 Introduction: Today, diagnostic ultrasound imaging is utilized immensely, vast utilization of this method in clinic necessitate the implementation of a QUALITY CONTROL program for diminishing diagnostic errors.Materials and Methods: In this study, by using the TEST OBJECT and proposed PERFORMANCE PROTOCOL, Seventy nine real time ultrasound systems have been evaluated in different hospitals in Tehran.The ultrasound systems were selected have evaluated randomly and evaluated in aspect of QUALITY CONTROL essential parameters.Results: The results were compared to AAPM (American Association of Physicists in Medicine) recommended values. The data showed that of total tested equipments 20.3% in dead zone, 64.6% in depth measurements, 54.4% in horizontal measurements, 19.0% in axial resolution, 12.7% in lateral resolution, 20.2% in focusing number and 30.4% in uniformity had no performance as compared to AAPM recommended values.Conclusions: These results showed that the maximum error was related to lateral and depth measurements and least error was related to lateral resolution. The presence of these considerable errors highlighted the necessity of performing a comprehensive QUALITY CONTROL program routinely for real-time diagnostic ultrasound imaging equipments.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MANTEGHI, F., SHARAFI, A.A., & MOKHTARI DIZAJI, M.. (2004). EVALUATION OF BASIC PARAMETERS OF REAL-TIME DIAGNOSTIC ULTRASOUND SYSTEMS. KOOMESH, 5(1-2), 73-80. SID. https://sid.ir/paper/37018/en

    Vancouver: Copy

    MANTEGHI F., SHARAFI A.A., MOKHTARI DIZAJI M.. EVALUATION OF BASIC PARAMETERS OF REAL-TIME DIAGNOSTIC ULTRASOUND SYSTEMS. KOOMESH[Internet]. 2004;5(1-2):73-80. Available from: https://sid.ir/paper/37018/en

    IEEE: Copy

    F. MANTEGHI, A.A. SHARAFI, and M. MOKHTARI DIZAJI, “EVALUATION OF BASIC PARAMETERS OF REAL-TIME DIAGNOSTIC ULTRASOUND SYSTEMS,” KOOMESH, vol. 5, no. 1-2, pp. 73–80, 2004, [Online]. Available: https://sid.ir/paper/37018/en