مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,914
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

147
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

CR (VI)/CR (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY

Pages

  125-130

Abstract

 A new technique of coupled electrodeposition-electrothermal Atomic Absorption Spectrometry (AAS) method has been developed to study chromium speciation. Speciation of Cr (VI)/Cr (III) is carried out by electrodeposition at uncontrolled applied potentials, followed by removal of spent electrolyte and atomisation. At Eappl = 0.5-10.0 V and using codeposition with Hg (and without Pd coating), only Cr (VI) is reduced to Cr (III) and accumulated as Cr (OH)3 by absorption onto mercury film on the graphite furnace. Total chromium is measured by electrodepositing at 10.0 V without Hg but on the renewable Pd substrate from 0.5 M NaCl and 1% H2SO4. It has been demonstrated that chromium speciation can be achieved in samples of 0.5 M NaCl, using acetate buffer to adjust pH to 4.7. The results also will be given for attempted chromium speciation studies by in situ deposition onto Pd-coated furnace. At all applied voltages between 2.0- 10.0 V in 0.02% H2SO4 Cr (III) is reduced to chromium metal and deposited onto the Pd substrate more efficiently than Cr (VI), but the difference is not sufficient for complete discrimination of two chromium forms. The effect of SO4 2- ion concentration and of pH on the yield of deposition were studied for each form of chromium. It was shown that from 1% H2SO4 both forms of chromium deposited quantitatively. Apart from achieving speciation, background signal due to high concentration of NaCl in the sample was completely eliminated by the proposed technique. At the same time a two-fold improvement in sensitivity of the determination was achieved with respect to the conventional electrothermal AAS technique.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MASHKOURI NAJAFI, N.. (2002). CR (VI)/CR (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY. JOURNAL OF SCIENCES ISLAMIC REPUBLIC OF IRAN, 13(2), 125-130. SID. https://sid.ir/paper/370754/en

    Vancouver: Copy

    MASHKOURI NAJAFI N.. CR (VI)/CR (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY. JOURNAL OF SCIENCES ISLAMIC REPUBLIC OF IRAN[Internet]. 2002;13(2):125-130. Available from: https://sid.ir/paper/370754/en

    IEEE: Copy

    N. MASHKOURI NAJAFI, “CR (VI)/CR (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY,” JOURNAL OF SCIENCES ISLAMIC REPUBLIC OF IRAN, vol. 13, no. 2, pp. 125–130, 2002, [Online]. Available: https://sid.ir/paper/370754/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button