مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

269
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Utilizing MPC Controlled Multilevel Neutral Point Clamped Rectifier for Supplying Loran Transmitter

Pages

  155-165

Keywords

Model Predictive Control (MPC)Q1

Abstract

 The present work studies a model predictive controlled two-and three-level active front-end rectifier system for supplying Loran Transmitter system. Up to now, the Loran Transmitters have been supplied by only diode rectifiers, which inject sever harmonics into the AC network and induce a very low input power factor when supplying Pulsed Loads. Therefore, an MPC-controlled active rectifier system with three level neutral point clamped topology is proposed to attenuate the input current harmonics and improve the input power factor. Compared with the conventional methods (e. g. voltage oriented control (VOC), direct power control (DPC)), the proposed control method provides such advantages as improved power quality indices, reduced switching frequency, and simplicity for controlling different indices just by changing the weighting factors of the relevant cost function. The results of comparing these thee methods demonstrate that the MPC method could not only give a power factor close to unity and negligible harmonic distortion, but also very lower switching frequency, as compared to the two other methods. Using the MPC, VOC, and DPC control methods, the switching frequencies for a typical load were found to be 11. 3, 74. 5, and 60 kHz, respectively. Moreover, the intuitive logic and easy implementation of the MPC method, compared to the two other ones, besides achieving an improved operating point with a lower cost, represent the other important advantages of the MPC method.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BEYGI, M., DEHESTANI KOLAGAR, A., & ALIZADEH PAHLAVANI, M.R.. (2020). Utilizing MPC Controlled Multilevel Neutral Point Clamped Rectifier for Supplying Loran Transmitter. (JOURNAL OF ADVANCED DEFENCE SCIENCE AND TECHNOLOGY) JOURNAL OF PASSIVE DEFENCE SCIENCE AND TECHNOLOGY, 11(2 ), 155-165. SID. https://sid.ir/paper/371774/en

    Vancouver: Copy

    BEYGI M., DEHESTANI KOLAGAR A., ALIZADEH PAHLAVANI M.R.. Utilizing MPC Controlled Multilevel Neutral Point Clamped Rectifier for Supplying Loran Transmitter. (JOURNAL OF ADVANCED DEFENCE SCIENCE AND TECHNOLOGY) JOURNAL OF PASSIVE DEFENCE SCIENCE AND TECHNOLOGY[Internet]. 2020;11(2 ):155-165. Available from: https://sid.ir/paper/371774/en

    IEEE: Copy

    M. BEYGI, A. DEHESTANI KOLAGAR, and M.R. ALIZADEH PAHLAVANI, “Utilizing MPC Controlled Multilevel Neutral Point Clamped Rectifier for Supplying Loran Transmitter,” (JOURNAL OF ADVANCED DEFENCE SCIENCE AND TECHNOLOGY) JOURNAL OF PASSIVE DEFENCE SCIENCE AND TECHNOLOGY, vol. 11, no. 2 , pp. 155–165, 2020, [Online]. Available: https://sid.ir/paper/371774/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top