مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

297
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Flow Energy Dissipation in Vortex Drop Shaft by Tangential Inlet

Pages

  2877-2888

Abstract

 Vortex Drop Shafts, with a primary function of dissipating flow energy, are used to transfer flow from higher to lower elevations. In the present research, the physical model of the vortex Drop Shaft of the eastern Tehran sewage system in Iran are studied and the effects of the inflow Froude number, inlet bottom slope, and the ratio of sump depth to vertical shaft diameter on the flow Energy Dissipation rate are surveyed. This study was performed with Froude numbers of 1. 79, 2. 01, 2. 18 and 2. 31, the inlet bottom slopes of 0. 251, 0. 4, and 0. 571, and the sump depth to vertical shaft diameter ratios of 0, 1, and 2. Accordingly, 36 experiments were designed. For the purpose of increasing accuracy and analysis of results, each experiment is repeated 3 times. Consequently, 108 experiments were done. The results showed that the flow energy is dissipated in the range of 93. 7% to 98. 5% by changing the parameters. In addition, increasing the inflow Froude number and the sump depth to vertical shaft diameter ratio cause the reduction of the flow Energy Dissipation rate in the vortex Drop Shaft by 2. 2% and 3%, respectively. Also, increasing the inlet bottom slope increases the flow Energy Dissipation rate by 2. 4%. According to the interaction between the flow Energy Dissipation and the outflow Froude number, the appropriate sump depth to vertical shaft diameter ratio proposed 0. 3-1. 2. Furthermore, a nonlinear relationship using the variance analysis was presented to estimate the flow Energy Dissipation rate.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HAJI AHMADI, AMIN, Ghaeini Hessaroeyeh, Mahnaz, & KHANJANI, MOHAMMAD JAVAD. (2021). Flow Energy Dissipation in Vortex Drop Shaft by Tangential Inlet. IRANIAN JOURNAL OF SOIL AND WATER RESEARCH, 51(11 ), 2877-2888. SID. https://sid.ir/paper/378218/en

    Vancouver: Copy

    HAJI AHMADI AMIN, Ghaeini Hessaroeyeh Mahnaz, KHANJANI MOHAMMAD JAVAD. Flow Energy Dissipation in Vortex Drop Shaft by Tangential Inlet. IRANIAN JOURNAL OF SOIL AND WATER RESEARCH[Internet]. 2021;51(11 ):2877-2888. Available from: https://sid.ir/paper/378218/en

    IEEE: Copy

    AMIN HAJI AHMADI, Mahnaz Ghaeini Hessaroeyeh, and MOHAMMAD JAVAD KHANJANI, “Flow Energy Dissipation in Vortex Drop Shaft by Tangential Inlet,” IRANIAN JOURNAL OF SOIL AND WATER RESEARCH, vol. 51, no. 11 , pp. 2877–2888, 2021, [Online]. Available: https://sid.ir/paper/378218/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top