مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

859
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A COMPARISON OF THE UPPER LIP BITE TEST WITH HYOMENTAL/ THYROSTERNAL DISTANCES AND MANDIBLE LENGTH IN PREDICTING DIFFICULTY IN INTUBATION

Pages

  432-437

Keywords

Not Registered.

Abstract

 Background: Difficulty in tracheal intubation has always been a problem in both elective and emergency setting. The aim of this study was to compare the newly designed test, the Upper Lip Bite Test, (ULBT) with prevailing Tests – the Hyomental /Thyrostemal distances ( HMD, TSD ) and the Mandible length (ML) in predicting difficulty in intubation.Methods and Materials: A total of 300 patients meeting the inclusion criteria were enrolled in this study. Each patient was assessed by a resident of Anesthesiology, regarding the ULBT, HMD, TSD and ML, and Laryngoscopy was Performed by the Anesthetics blinded to the measurements obtained and grading recorded using the Cormack and Lehane laryngoscopic grading system. The data obtained were analyzed using chi square and ANOVA. Results: The results showed 11.3% incidence of difficult intubation. Sensitivity and Specificity of ULBT were 94% and 100% respectively, being the highest compared to TSD which were the lowest being 88% and zero percent. respectively .ULBT class III had a direct correlation with HMD<3.5cm (p=0.00), and ML < 9cm (p<0.01). ULBT had the highest positive and negative predictive values (100% and 47%) respectively. Accuracy of ULBT was found to be 94%, again the highest among the four tests.Coclusion: In conclusion, ULBT was found to have the highest Sensitivity and Specificity and accuracy, and could be used as a single bed test in predicting difficulty in intubation.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HOSSEINKHAN, ZAHED, & MALEKI, A.. (2005). A COMPARISON OF THE UPPER LIP BITE TEST WITH HYOMENTAL/ THYROSTERNAL DISTANCES AND MANDIBLE LENGTH IN PREDICTING DIFFICULTY IN INTUBATION. TEHRAN UNIVERSITY MEDICAL JOURNAL (TUMJ), 63(6), 432-437. SID. https://sid.ir/paper/39024/en

    Vancouver: Copy

    HOSSEINKHAN ZAHED, MALEKI A.. A COMPARISON OF THE UPPER LIP BITE TEST WITH HYOMENTAL/ THYROSTERNAL DISTANCES AND MANDIBLE LENGTH IN PREDICTING DIFFICULTY IN INTUBATION. TEHRAN UNIVERSITY MEDICAL JOURNAL (TUMJ)[Internet]. 2005;63(6):432-437. Available from: https://sid.ir/paper/39024/en

    IEEE: Copy

    ZAHED HOSSEINKHAN, and A. MALEKI, “A COMPARISON OF THE UPPER LIP BITE TEST WITH HYOMENTAL/ THYROSTERNAL DISTANCES AND MANDIBLE LENGTH IN PREDICTING DIFFICULTY IN INTUBATION,” TEHRAN UNIVERSITY MEDICAL JOURNAL (TUMJ), vol. 63, no. 6, pp. 432–437, 2005, [Online]. Available: https://sid.ir/paper/39024/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button