مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

750
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE COMPARISON OF DIFFERENT INTER IMPLANT DISTANCES ON RETENTION VALUE OF LOCATOR ATTACHMENT IN IMPLANT SUPPORTED OVER DENTURES

Pages

  0-0

Abstract

 Background and Objective: Using 2 implants in edentulous lower jaw is a standard protocol treatment for improvement of prosthesis RETENTION. Different attachments have been produced in factories. One of these attachments is locator that is now a famous clinical option. In this in vitro study, the effect of inter implant distance on RETENTION in simulated function condition and on 2 brands including Dio and 3i is analyzed.Materials and Methods: In this study, 24 nylon inserts pairs were provided from dio and 3i system attachment. Then, 2 hollow blocks with parallel walls were constructed. Attachments splinted to analogue and assembly inserted in block with GC reline materials in 2 inter implant distances of 19 and 23 mm and parallelism has confirmed with jelenko surveyor. The samples were assembled in zwick jaws and every sample was loaded at 1440 cyclic loading from vertical. Data is measured at cycles of zero, 120, 360, 720, and 1440 with 34560 cyclic loading exerted. Data were analyzed with proper statistical tests.Results and Conclusion: The results were analyzed with one-way analysis of variance (ANOVA). It was found out that RETENTION value in 23 mm distance was greater than 19 mm until 720 cycles and difference was significant but at 1440 cycles, there was no significant difference.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    KHALILPOUR, MOHAMMAD, SALARI, ALIMOHAMMAD, & SHAYEGH, SEYYED SHOJAODIN. (2012). THE COMPARISON OF DIFFERENT INTER IMPLANT DISTANCES ON RETENTION VALUE OF LOCATOR ATTACHMENT IN IMPLANT SUPPORTED OVER DENTURES. DANESHVAR MEDICINE, 20(103), 0-0. SID. https://sid.ir/paper/403984/en

    Vancouver: Copy

    KHALILPOUR MOHAMMAD, SALARI ALIMOHAMMAD, SHAYEGH SEYYED SHOJAODIN. THE COMPARISON OF DIFFERENT INTER IMPLANT DISTANCES ON RETENTION VALUE OF LOCATOR ATTACHMENT IN IMPLANT SUPPORTED OVER DENTURES. DANESHVAR MEDICINE[Internet]. 2012;20(103):0-0. Available from: https://sid.ir/paper/403984/en

    IEEE: Copy

    MOHAMMAD KHALILPOUR, ALIMOHAMMAD SALARI, and SEYYED SHOJAODIN SHAYEGH, “THE COMPARISON OF DIFFERENT INTER IMPLANT DISTANCES ON RETENTION VALUE OF LOCATOR ATTACHMENT IN IMPLANT SUPPORTED OVER DENTURES,” DANESHVAR MEDICINE, vol. 20, no. 103, pp. 0–0, 2012, [Online]. Available: https://sid.ir/paper/403984/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button