مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

495
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Improve seismic performance of Concrete Moment Frame Structures using TLD damper

Pages

  49-57

Abstract

 In this paper, the effect of using a (TLD) damper on the seismic behavior of the Concrete Moment Frame Structures is investigated. Modeling ANSYS software is done. Modeling with structural elements including beams and columns in a concrete framing frame of Beam 189 and a Nonlinear Dynamic Analysis was used. The seismic behavior of the structures was investigated under the earthquakes of Kobe, Chichi and Tabas. The TLD Damper in the 5, 10 and 15 buildings were compared and compared. The effect of different damper positions on different structures of the structures was investigated. The effect of different damper positions on different structures of the structures was investigated. Using of a damper can cause plastic joint failure in the joints. It was also found that depression position is an effective parameter on the seismic behavior of the studied structures. For the 15th floor structure, the use of a damper on the fifth floor of the structure reduces the roof structure displacement by 10. 5, in the fifth floor, 17 percent, and 53 percent in the fifth floor. In the structure of the ten floors of the dam, it reduces the displacement of the roof structure by 50%. In the 10-story structure, the dampers in the 5-day delay reduce the roof's displacement by 33%. In the five-story structure, the use of a barrier on the 5th floor decreases the roof by 64%, and the position of the damper on the third floor leads to a 26% decrease in the structure's roof.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    Sarmad, Ali, & Movahednia, Mehrdad. (2019). Improve seismic performance of Concrete Moment Frame Structures using TLD damper. JOURNAL OF STRUCTURAL ENGINEERING, 16(2 ), 49-57. SID. https://sid.ir/paper/406357/en

    Vancouver: Copy

    Sarmad Ali, Movahednia Mehrdad. Improve seismic performance of Concrete Moment Frame Structures using TLD damper. JOURNAL OF STRUCTURAL ENGINEERING[Internet]. 2019;16(2 ):49-57. Available from: https://sid.ir/paper/406357/en

    IEEE: Copy

    Ali Sarmad, and Mehrdad Movahednia, “Improve seismic performance of Concrete Moment Frame Structures using TLD damper,” JOURNAL OF STRUCTURAL ENGINEERING, vol. 16, no. 2 , pp. 49–57, 2019, [Online]. Available: https://sid.ir/paper/406357/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button