مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

403
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Comparing Sensitivity and Specificity of Liquid-Based and Conventional Cytology Smears in Fine Needle Aspirates for Diagnosis of Breast Mass

Pages

  34-39

Abstract

 Introduction: This study aimed to compare the cytology results obtained by the conventional smear method with those obtained by the liquid-based method for the diagnosis of palpable Breast Masses in women referred to the clinic of Shahid Mohammadi Hospital in Bandar Abbas city. Methods: The research method was descriptive– cross-sectional. The research sample was selected based on purposive and availability sampling. Accordingly, 67 patients referred to the surgical clinic of Shahid Mohammadi Hospital in 2019-2020 were evaluated. The diagnostic sensitivity, diagnostic specificity, positive predictive value, and negative predictive value of conventional smear method and liquidbased method were compared. Results: The diagnostic sensitivity of the conventional smear method was 88. 4%, specificity 94. 9%, positive predictive value 92%, and negative predictive value 92. 5%. The diagnostic sensitivity of the liquid-based method was 84%, specificity 90%, positive predictive value 80. 7%, and negative predictive value 90%. Conclusion: Liquid-based method is better than conventional smear because of the ease of processing, faster screening, and preservation of cells and nuclear details. And it can be a promising and reliable method to diagnose palpable Breast Masses before surgery.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    JAFAR AGHAEI, M., SAJJADI, H., DEHGHANI ZAHEDANI, M., BANIHASHEMI, H., & Booshehri, E.. (2021). Comparing Sensitivity and Specificity of Liquid-Based and Conventional Cytology Smears in Fine Needle Aspirates for Diagnosis of Breast Mass. IRANIAN QUARTERLY JOURNAL OF BREAST DISEASE, 13(4 (51) ), 34-39. SID. https://sid.ir/paper/407258/en

    Vancouver: Copy

    JAFAR AGHAEI M., SAJJADI H., DEHGHANI ZAHEDANI M., BANIHASHEMI H., Booshehri E.. Comparing Sensitivity and Specificity of Liquid-Based and Conventional Cytology Smears in Fine Needle Aspirates for Diagnosis of Breast Mass. IRANIAN QUARTERLY JOURNAL OF BREAST DISEASE[Internet]. 2021;13(4 (51) ):34-39. Available from: https://sid.ir/paper/407258/en

    IEEE: Copy

    M. JAFAR AGHAEI, H. SAJJADI, M. DEHGHANI ZAHEDANI, H. BANIHASHEMI, and E. Booshehri, “Comparing Sensitivity and Specificity of Liquid-Based and Conventional Cytology Smears in Fine Needle Aspirates for Diagnosis of Breast Mass,” IRANIAN QUARTERLY JOURNAL OF BREAST DISEASE, vol. 13, no. 4 (51) , pp. 34–39, 2021, [Online]. Available: https://sid.ir/paper/407258/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button