مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

814
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARATIVE ANALYSIS OF USING ELECTROCAUTER AND SCALPEL IN MIDINE LAPAROTOMY PATIENTS WHO REFFERED OF LOGHMAN HAKIM HOSPITAL (2012 TO 2013)

Pages

  212-216

Abstract

 Introduction: For many years SURGICAL INCISIONs were done by SCALPEL. Nowadays this method has been replaced with ELECTROCAUTERy. Each of these methods has their disadvantages and benefits. The purpose of this study is to compare these two methods in midline laparotomy surgeries.Methods: From 2012 until 2013, One hundred patients enter the study, underwent midline laparotomy and were divided into two Groups. In one group SCALPEL and in the other group ELECTROCAUTERy were used. The speed of surgical resection, bleeding, postoperative pain and other wound complications were compared between two groups.Results: In this study, the mean and standard deviation speed was calculated based on centimeter per minutes. In Electracautery group result was 10.64±3.052 and in SCALPEL group was 8.26±3.61. The average And standard deviation of the bleeding based on number of bloody used gauzes in Electracautery group was 0.97±0.37 and in other group was 2.26±1.25.Wound complications among the patients with ELECTROCAUTER usage were 8.2% versus 11.8% in the other group.Conclusion: Amount of pain and wound complication were similar in two groups. However, using ELECTROCAUTERy device increases the speed of operation and decreases bleeding amount. Therefore, surgical SCALPEL can be replaced by ELECTROCAUTER.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    PEYVANDI, HASSAN, MIRHASHEMI, SEYYED HADI, SOURI, MOHSEN, KHALAJ, ELHAM, SHAMS AKHTARI, AMIN, NADERI, KAVEH, & HAJINASROLLAH, SEYYED ESMAEIL. (2015). COMPARATIVE ANALYSIS OF USING ELECTROCAUTER AND SCALPEL IN MIDINE LAPAROTOMY PATIENTS WHO REFFERED OF LOGHMAN HAKIM HOSPITAL (2012 TO 2013). JOURNAL OF MEDICAL COUNCIL OF I.R.I., 33(3), 212-216. SID. https://sid.ir/paper/41482/en

    Vancouver: Copy

    PEYVANDI HASSAN, MIRHASHEMI SEYYED HADI, SOURI MOHSEN, KHALAJ ELHAM, SHAMS AKHTARI AMIN, NADERI KAVEH, HAJINASROLLAH SEYYED ESMAEIL. COMPARATIVE ANALYSIS OF USING ELECTROCAUTER AND SCALPEL IN MIDINE LAPAROTOMY PATIENTS WHO REFFERED OF LOGHMAN HAKIM HOSPITAL (2012 TO 2013). JOURNAL OF MEDICAL COUNCIL OF I.R.I.[Internet]. 2015;33(3):212-216. Available from: https://sid.ir/paper/41482/en

    IEEE: Copy

    HASSAN PEYVANDI, SEYYED HADI MIRHASHEMI, MOHSEN SOURI, ELHAM KHALAJ, AMIN SHAMS AKHTARI, KAVEH NADERI, and SEYYED ESMAEIL HAJINASROLLAH, “COMPARATIVE ANALYSIS OF USING ELECTROCAUTER AND SCALPEL IN MIDINE LAPAROTOMY PATIENTS WHO REFFERED OF LOGHMAN HAKIM HOSPITAL (2012 TO 2013),” JOURNAL OF MEDICAL COUNCIL OF I.R.I., vol. 33, no. 3, pp. 212–216, 2015, [Online]. Available: https://sid.ir/paper/41482/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top