Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

946
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

MEASUREMENT OF INTRAOCULAR PRESSURE USING SCHIOTZ VS TONO-PEN TONOMETERS IN PATIENTS WITH PRIMARY CONGENITAL GLAUCOMA

Pages

  222-226

Abstract

 Purpose: To compare the TONO-PEN and SCHIOTZ tonometers in measurement of intraocular pressure (IOP) in patients with primary CONGENITAL GLAUCOMA.Methods: This study was conducted on 38 eyes of 20 patients with primary CONGENITAL GLAUCOMA. All measurements were performed under general anesthesia. One minute after receiving Halothane 3% IOP was determined by TONO-PEN and then by SCHIOTZ tonometers. Data were analyzed by regression analysis and Bland-Altman bias plot.Results: Mean age of patients was 19.4±14.5 months and 15 (75%) of them were male. Glaucoma was bilateral in 18 (90%) and unilateral in 2 (10%) subjects. Mean IOP measured by TONO-PEN and SCHIOTZ tonometers was 19.39±8.51 and 18.84±8.9 mmHg, respectively. These tonometers had good concordance in determination of IOP in primary CONGENITAL GLAUCOMA according to the results of regression analysis and Bland-Altman bias plot.Conclusion: Considering the sample size of this study, the TONO-PEN and SCHIOTZ tonometers are highly concordant regarding intraocular pressure measurement in children with primary CONGENITAL GLAUCOMA.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    AMINI, HEYDAR, AMINI, N., RAZEGHINEZHAD, M.R., ZAREE, R., FARAJI OSKOOYEE, J., & TABATABAEI, S.H.R.. (2005). MEASUREMENT OF INTRAOCULAR PRESSURE USING SCHIOTZ VS TONO-PEN TONOMETERS IN PATIENTS WITH PRIMARY CONGENITAL GLAUCOMA. BINA, 11(2 (43)), 222-226. SID. https://sid.ir/paper/42267/en

    Vancouver: Copy

    AMINI HEYDAR, AMINI N., RAZEGHINEZHAD M.R., ZAREE R., FARAJI OSKOOYEE J., TABATABAEI S.H.R.. MEASUREMENT OF INTRAOCULAR PRESSURE USING SCHIOTZ VS TONO-PEN TONOMETERS IN PATIENTS WITH PRIMARY CONGENITAL GLAUCOMA. BINA[Internet]. 2005;11(2 (43)):222-226. Available from: https://sid.ir/paper/42267/en

    IEEE: Copy

    HEYDAR AMINI, N. AMINI, M.R. RAZEGHINEZHAD, R. ZAREE, J. FARAJI OSKOOYEE, and S.H.R. TABATABAEI, “MEASUREMENT OF INTRAOCULAR PRESSURE USING SCHIOTZ VS TONO-PEN TONOMETERS IN PATIENTS WITH PRIMARY CONGENITAL GLAUCOMA,” BINA, vol. 11, no. 2 (43), pp. 222–226, 2005, [Online]. Available: https://sid.ir/paper/42267/en