Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Journal Paper

Paper Information

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,474
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT WITH THE NONCONTACT PULSAIR 3000 TONOMETER AND GOLDMANN APPLANATION TONOMETER

Pages

  372-377

Keywords

Not Registered.

Abstract

 Purpose: To compare intraocular pressure (IOP) measurement with Pulsair non-contact tonometer and Goldmann applanation tonometer (GAT). Methods: In this cross-sectional study, during a complete ophthalmologic examination, each patient underwent Pulsair tonometry three times at 5 minutes intervals and then Goldmann tonometry at the same intervals. Mean IOP values were measured and analyzed. Results: We evaluated 458 eyes of 250 patients (138 males and 112 female subjects). Mean IOP was 19.45±9.04 mmHg with GAT and 20.11±8.42 mmHg with Pulsair (P=0.075). Correlation coefficient between the two methods was 0.96 (P= 0.004) and the mean difference (Pulsair-GAT) was 0.65±1.52 (confidence interval 95%, +3.5 to -2.29). With IOPs between 10-25mmHg, mean difference between the two methods was 0.49±1.23 (P= 0.32) mmHg, however it was -1.75±1.91 (P= 0.06) at IOPs over than 25 mm Hg. Conclusion: Pulsair tonometry has acceptable accuracy in comparison with GAT, especially in IOP ranging from 10 to 25 mmHg.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    RAZMJOU, H., RAZMJOU, M., TAVAKOLI, MAHDI, AKHLAGHI, M.R., RISMANCHIAN, A., DEHGHANI, A.R., & NASR ELAHI, K.. (2009). COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT WITH THE NONCONTACT PULSAIR 3000 TONOMETER AND GOLDMANN APPLANATION TONOMETER. BINA, 14(4 (57)), 372-377. SID. https://sid.ir/paper/42955/en

    Vancouver: Copy

    RAZMJOU H., RAZMJOU M., TAVAKOLI MAHDI, AKHLAGHI M.R., RISMANCHIAN A., DEHGHANI A.R., NASR ELAHI K.. COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT WITH THE NONCONTACT PULSAIR 3000 TONOMETER AND GOLDMANN APPLANATION TONOMETER. BINA[Internet]. 2009;14(4 (57)):372-377. Available from: https://sid.ir/paper/42955/en

    IEEE: Copy

    H. RAZMJOU, M. RAZMJOU, MAHDI TAVAKOLI, M.R. AKHLAGHI, A. RISMANCHIAN, A.R. DEHGHANI, and K. NASR ELAHI, “COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT WITH THE NONCONTACT PULSAIR 3000 TONOMETER AND GOLDMANN APPLANATION TONOMETER,” BINA, vol. 14, no. 4 (57), pp. 372–377, 2009, [Online]. Available: https://sid.ir/paper/42955/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    مرکز اطلاعات علمی SID
    strs
    دانشگاه امام حسین
    بنیاد ملی بازیهای رایانه ای
    کلید پژوه
    ایران سرچ
    ایران سرچ
    File Not Exists.
    Move to top