مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

921
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

A MODIFIED SYNCHRONIZED VOLTAGE MEASUREMENT BASED TECHNIQUE FOR FAULT LOCATION ON TWO–TERMINAL LINES ACCOMPANIED BY CT ELIMINATION

Pages

  45-56

Abstract

 This paper presents a new FAULT LOCATION method based on synchronized phasor measurement for two–terminal transmission lines. Due to some common problems of current transformers (CT) in power system protection such as low accuracy, this method wipes off the CT requirement. In other word, the method is only based on voltage measurement. Samples of voltage at both ends of line are taken synchronously and used to calculate the location of fault. The algorithm uses thevenin equivalent model of faulted system and SYMMETRICAL COMPONENTS theory for estimation of fault distance with reasonable error (0.7%). The proposed method is also independent of fault type, fault resistance, fault inception angle and line angle. In addition to these advantages, the proposed technique is improved by using MODIFIED algorithm in order to reduce the estimation error to less than one meter. Simulations with EMTP/ATP were performed to verify the accuracy of the proposed method.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    GORGANI FIROUZJAH, KH., & SHEYKH ALESLAMI, A.A.R.. (2008). A MODIFIED SYNCHRONIZED VOLTAGE MEASUREMENT BASED TECHNIQUE FOR FAULT LOCATION ON TWO–TERMINAL LINES ACCOMPANIED BY CT ELIMINATION. JOURNAL OF FACULTY OF ENGINEERING (UNIVERSITY OF TABRIZ), 36(1 (53) ELECTRICAL ENGINEERING), 45-56. SID. https://sid.ir/paper/43751/en

    Vancouver: Copy

    GORGANI FIROUZJAH KH., SHEYKH ALESLAMI A.A.R.. A MODIFIED SYNCHRONIZED VOLTAGE MEASUREMENT BASED TECHNIQUE FOR FAULT LOCATION ON TWO–TERMINAL LINES ACCOMPANIED BY CT ELIMINATION. JOURNAL OF FACULTY OF ENGINEERING (UNIVERSITY OF TABRIZ)[Internet]. 2008;36(1 (53) ELECTRICAL ENGINEERING):45-56. Available from: https://sid.ir/paper/43751/en

    IEEE: Copy

    KH. GORGANI FIROUZJAH, and A.A.R. SHEYKH ALESLAMI, “A MODIFIED SYNCHRONIZED VOLTAGE MEASUREMENT BASED TECHNIQUE FOR FAULT LOCATION ON TWO–TERMINAL LINES ACCOMPANIED BY CT ELIMINATION,” JOURNAL OF FACULTY OF ENGINEERING (UNIVERSITY OF TABRIZ), vol. 36, no. 1 (53) ELECTRICAL ENGINEERING, pp. 45–56, 2008, [Online]. Available: https://sid.ir/paper/43751/en

    Related Journal Papers

    Related Seminar Papers

    Related Plans

  • No record.
  • Recommended Workshops






    Move to top