مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

826
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON OF DYNAMIC CONTOUR TONOMETERY WITH GOLDMANN APPLANATION TONOMETRY BEFORE AND AFTER KERATOREFRACTIVE SURGERY

Pages

  15-22

Abstract

 Purpose: The dynamic contour tonometer (DCT) is a novel tonometer designed to measure lOP independent of corneal properties. The purpose of this study is a comparisonof lOP measured with the DCT and the GOLDMANN APPLANATION TONOMETRY (GAT), before and after keratorefractive surgery.Materials & Methods: In a cross-sectional study of 154 myopic and myopic astigmatism eyes, central corneal thickness (CCT) was measured ultrasonically and lOP measured before and 1 month after LASIK and PRK with DCT and GAT. The correlation between these two methods with each other and eachone with CCT analyzed with linear regression and Pearson Correlation.Results: Mean lOP before surgery with GAT was 17.85±2.64mmHg and after surgery was 13.56±2.64mmHg. Mean lOP before surgery with DCT was 18.79±3.5mmHg and after surgery was 17.39±3.5mm Hg. Corneal ablation of 90.4±5 Micron, reduced lOP readings by GAT and DCT, but this Reduction was significant in GAT in comparison with DCT (P<0.0001).Conclusion: CCT and corneal rigidity causes an error in tonometery. DCT can measure real lOP reading and independent from corneal properties. This study revealed that the lOP measurement with DCT has no Correlation with CCT. (Pearson correlation r=-0.4 and p=0.5).

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    HASHEMI, HASAN, BEHESHTNEZHAD, A.H., & LOTFI SEDIGH, A.. (2006). COMPARISON OF DYNAMIC CONTOUR TONOMETERY WITH GOLDMANN APPLANATION TONOMETRY BEFORE AND AFTER KERATOREFRACTIVE SURGERY. JOURNAL OF CURRENT OPHTHALMOLOGY, 19(1), 15-22. SID. https://sid.ir/paper/53093/en

    Vancouver: Copy

    HASHEMI HASAN, BEHESHTNEZHAD A.H., LOTFI SEDIGH A.. COMPARISON OF DYNAMIC CONTOUR TONOMETERY WITH GOLDMANN APPLANATION TONOMETRY BEFORE AND AFTER KERATOREFRACTIVE SURGERY. JOURNAL OF CURRENT OPHTHALMOLOGY[Internet]. 2006;19(1):15-22. Available from: https://sid.ir/paper/53093/en

    IEEE: Copy

    HASAN HASHEMI, A.H. BEHESHTNEZHAD, and A. LOTFI SEDIGH, “COMPARISON OF DYNAMIC CONTOUR TONOMETERY WITH GOLDMANN APPLANATION TONOMETRY BEFORE AND AFTER KERATOREFRACTIVE SURGERY,” JOURNAL OF CURRENT OPHTHALMOLOGY, vol. 19, no. 1, pp. 15–22, 2006, [Online]. Available: https://sid.ir/paper/53093/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    مرکز اطلاعات علمی SID
    strs
    دانشگاه امام حسین
    بنیاد ملی بازیهای رایانه ای
    کلید پژوه
    ایران سرچ
    ایران سرچ
    File Not Exists.
    Move to top