مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

311
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

142
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

EARLY TRANSIENT NEONATAL CYANOSIS RELATED TO INTERATRIAL RIGHT-TO-LEFT SHUNTING AT AN ALTITUDE OF 1890 METERS: A REPORT OF FIVE CASES (CASE REPORT)

Pages

  239-243

Abstract

 Background: We report five term NEONATEs born at an ALTITUDE of 1890 meters with transient early neonatal CYANOSIS due to right-to-left shunting at atrial level through patent foramen ovale.Case Presentation: The five NEONATEs with no clinical sign or symptom other than marked CYANOSIS were examined in two neonatal units of Erzurum city. Hematologic and radiologic examinations were normal. Partial oxygen pressure (PO2) in the arterial blood samples was lower than 45 mmHg in all of the patients, and did not increase more than 15 mmHg in any of the patients after inhalation of 100% oxygen. Echocardiography revealed normal intracardiac structure. The right-to-left interatrial shunt at diastole was detected through a patent foramen ovale in all of these infants. By only observation with no treatment, diastolic right-to-left shunt disappeared in 40.15±9.52 hours. Oxygen saturation was increased from 69.80±9.55 percent to 90.40±8.80 percent. The patients were discharged from the hospital at 5.6±0.4 days of life. Follow up for 6 months revealed no clinical problem in any of the cases.Conclusion: Transient CYANOSIS can be seen in the very early neonatal period because of interatrial right-to-left shunting in some healthy term NEONATEs born at an ALTITUDE of 1890 meters. Decreased right atrial compliance due to relative hypoxia at that ALTITUDE can be speculated to be the causative mechanism.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ZEYBEK, CENAP, KAHVECI, HASAN, GOKCE, IBRAHIM, BOGA, AYSUN, PAYASLI, MUGE, & KESKIN, HALIL. (2011). EARLY TRANSIENT NEONATAL CYANOSIS RELATED TO INTERATRIAL RIGHT-TO-LEFT SHUNTING AT AN ALTITUDE OF 1890 METERS: A REPORT OF FIVE CASES (CASE REPORT). IRANIAN JOURNAL OF PEDIATRICS, 21(2), 239-243. SID. https://sid.ir/paper/565490/en

    Vancouver: Copy

    ZEYBEK CENAP, KAHVECI HASAN, GOKCE IBRAHIM, BOGA AYSUN, PAYASLI MUGE, KESKIN HALIL. EARLY TRANSIENT NEONATAL CYANOSIS RELATED TO INTERATRIAL RIGHT-TO-LEFT SHUNTING AT AN ALTITUDE OF 1890 METERS: A REPORT OF FIVE CASES (CASE REPORT). IRANIAN JOURNAL OF PEDIATRICS[Internet]. 2011;21(2):239-243. Available from: https://sid.ir/paper/565490/en

    IEEE: Copy

    CENAP ZEYBEK, HASAN KAHVECI, IBRAHIM GOKCE, AYSUN BOGA, MUGE PAYASLI, and HALIL KESKIN, “EARLY TRANSIENT NEONATAL CYANOSIS RELATED TO INTERATRIAL RIGHT-TO-LEFT SHUNTING AT AN ALTITUDE OF 1890 METERS: A REPORT OF FIVE CASES (CASE REPORT),” IRANIAN JOURNAL OF PEDIATRICS, vol. 21, no. 2, pp. 239–243, 2011, [Online]. Available: https://sid.ir/paper/565490/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button