مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

559
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

128
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE EFFECT OF IMPLANT POSITION ON RETENTION AND STABILITY OF MANDIBULAR IMPLANT-SUPPORTED OVERDENTURES

Pages

  41-51

Abstract

 Objective: Implant-retained overdenture is the standard of treatment of edentulous patients. The aim of this study was to compare the effect of different implant location (ABDE, 6AE6, 6BD6) on the RETENTION and STABILITY of mandibular implant overdenture with ball attachment.Methods: An experimental study was designed. An acrylic resin model of edentulous mandible with six implant in the location of first molars, first premolar and between lateral incisor and canine on the left and right side was fabricated. A metallic overdenture was fabricated precisely adapted to the model and attached to a Zwick testing machine (crosshead speed of 51 mm/min). The ball attachments were screw in three patterns. The balls were first screwed in ABDE, then in 6AE6, and finally in 6BD6 position. Dislodging tensile forces were applied in three vertical, oblique, anterior-posterior directions for each sample. For each of these three situations, five tests were done. The maximum dislodging force was measured. Normal distributions of data were analyzed with Shapiro-Wilk test. Levene’s test analyzed the variances. A Three-way ANOVA test was employed followed by Tukey’s test.Results: The amount of vertical load was significantly higher than the oblique and Anterior-posterior load (P<0.001). The amount of ant-post load is significantly higher than the oblique load (P<0.001). The average of MDF is significantly higher in 6BD6 position (P<0.001). This average was also significantly lower in ABDE position (P<0.001). The amount of measured force was the lowest in ABDE and the highest in 6BD6 positions (ABDE=64.51 N and 6AE6=66.06 N). Vertical and oblique dislodging force are the minimum and maximum measured forces respectively (mean vertical= 87.95 N, mean Lateral= 48.1 N and mean Ant. Post= 63.5 N).Conclusion: Lateral and Ant-Post dislodgment forces are higher in 6BD6 and 6AE6 positions respectively. The greatest vertical dislodgment force was observed in 6BD6 position. Vertical RETENTION was higher than lateral and Ant-Post RETENTIONs. The more posterior position the distal implant the more the RETENTION and STABILITY.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    SADR, SEYYED JALIL, SABOURY, ABOLFAZL, HADI, ALIREZA, & MAHSHID, MINOO. (2012). THE EFFECT OF IMPLANT POSITION ON RETENTION AND STABILITY OF MANDIBULAR IMPLANT-SUPPORTED OVERDENTURES. JOURNAL OF DENTAL SCHOOL SHAHID BEHESHTI UNIVERSITY OF MEDICAL SCIENCE, 30(1 (91)), 41-51. SID. https://sid.ir/paper/579670/en

    Vancouver: Copy

    SADR SEYYED JALIL, SABOURY ABOLFAZL, HADI ALIREZA, MAHSHID MINOO. THE EFFECT OF IMPLANT POSITION ON RETENTION AND STABILITY OF MANDIBULAR IMPLANT-SUPPORTED OVERDENTURES. JOURNAL OF DENTAL SCHOOL SHAHID BEHESHTI UNIVERSITY OF MEDICAL SCIENCE[Internet]. 2012;30(1 (91)):41-51. Available from: https://sid.ir/paper/579670/en

    IEEE: Copy

    SEYYED JALIL SADR, ABOLFAZL SABOURY, ALIREZA HADI, and MINOO MAHSHID, “THE EFFECT OF IMPLANT POSITION ON RETENTION AND STABILITY OF MANDIBULAR IMPLANT-SUPPORTED OVERDENTURES,” JOURNAL OF DENTAL SCHOOL SHAHID BEHESHTI UNIVERSITY OF MEDICAL SCIENCE, vol. 30, no. 1 (91), pp. 41–51, 2012, [Online]. Available: https://sid.ir/paper/579670/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button