مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,274
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

COMPARISON BETWEEN M-MODE AND DOPPLER ECHOCARDIOGRAPHY IN DIAGNOSIS OF PATENT DUCTUS ARTERIOSUS IN CHILDREN

Pages

  129-132

Abstract

 Introduction: PATENT ducfus arteriosus (PDA) is the persistence of a normal fetal structure between left pulmonary artery and descending aorta. Persistence of this fetal structure beyond 10 days of life is considered abnormal. In this study we compared M-Mode and DOPPLER ECHOCARDIOGRAPHY in diagnosis of PDA in children at Aliasghar Hospital in Zahedan and Children hospital in Bandar Abbas for one year. methods: We selected 62 patients that were suspicious to have PDA on physical examination. It should be mentioned that we omitted patients with other cgngenital cardiac abnormalities such as truncus arteriosus, ASD, VSD and AZSD. Our patients were below 15years old. Before ECHOCARDIOGRAPHY, physical examination, CXR and ECG were done for the patients. Then, they were evluated with both M-Mode and DOPPLER ECHOCARDIOGRAPHY and finally results were statistically analyzed.Results: Out of 62 patients, 34 were female and 28 were male. 51.6% patients were less than one year old and others were older. 85% of patients had cardiac murmur on physical examination and in 50% of them pulmonary component of second heart sound was increased. Peripheral pounding pulses were present in 85% of patients. In chest X-Ray, 82.3% of patients had increased cardiothoracic ratio and pulmonary vascular markings were increased in 85.5% of them. On ECG, 58.1 % of patients had signs of right and left or bilateral ventricular hypertrophy. Pulmonary hypertension was also seen in 51.6% of patients. PDA was diagnosed with M-Mode ECHOCARDIOGRAPHY in 56 patients (90.3 %) and with DOPPLER ECHOCARDIOGRAPHY in 61 patients (98.4%). According to McNemar statistical analysis, there was not an obvious difference between these two. methods of ECHOCARDIOGRAPHY in PDA diagnosis (p=0.125).Conclusion: Findings of this study showed that M-Mode and DOPPLER ECHOCARDIOGRAPHY for diagnosis of PDA in children are similar and again attention to M-Mode ECHOCARDIOGRAPHY can be helpful in diagnosis of PDA in children especially restless infants and neonates.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    RAJAEI, SH., & NOURI, NOUR MOHAMMAD. (2004). COMPARISON BETWEEN M-MODE AND DOPPLER ECHOCARDIOGRAPHY IN DIAGNOSIS OF PATENT DUCTUS ARTERIOSUS IN CHILDREN. HORMOZGAN MEDICAL JOURNAL, 8(3), 129-132. SID. https://sid.ir/paper/60464/en

    Vancouver: Copy

    RAJAEI SH., NOURI NOUR MOHAMMAD. COMPARISON BETWEEN M-MODE AND DOPPLER ECHOCARDIOGRAPHY IN DIAGNOSIS OF PATENT DUCTUS ARTERIOSUS IN CHILDREN. HORMOZGAN MEDICAL JOURNAL[Internet]. 2004;8(3):129-132. Available from: https://sid.ir/paper/60464/en

    IEEE: Copy

    SH. RAJAEI, and NOUR MOHAMMAD NOURI, “COMPARISON BETWEEN M-MODE AND DOPPLER ECHOCARDIOGRAPHY IN DIAGNOSIS OF PATENT DUCTUS ARTERIOSUS IN CHILDREN,” HORMOZGAN MEDICAL JOURNAL, vol. 8, no. 3, pp. 129–132, 2004, [Online]. Available: https://sid.ir/paper/60464/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button