مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,150
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

ROLE OF DIAGNOSTIC TOOLS (SONOGRAPHY & DPL) IN BLUNT ABDOMINAL TRAUMA (A 5 YEARS REPORT)

Pages

  136-141

Abstract

 Introduction: BLUNT ABDOMINAL TRAUMA is one of the most common mechanisms of trauma especially in motor vehicle accidents. Diagnostic problems are the matter of concern in these patients. There are many reports about the accuracy of diagnostic tools considering the decrease in the rate of negative laparotomies at the same time.Materials and methods: In this study all emergency laparotomies of a referral hospital are evaluated in a 5 years period retrospectively (1996-2000).Results: There were 61 positive and 14 negative (18.7%) laparotomies in 75 patients. 4 patients underwent nontherapeutic laparotomy because of retroperitoneal hematoma. SONOGRAPHY was done in 34 cases with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) as 84.3%, 50%, 96.4% and 16.6%, respectively. Diagnostic peritoneal lavage (DPL) which was done for 16 patients had 100% sensitivity, 66.7% 5pecificity, 92.8% PPVand 100% NPV. There were 9 negative laparotomies (32.2%) in 28 patients whom were operated on the basis of clinical findings merely.Discussions: We concluded that SONOGRAPHY is a valuable tool for initial assessment of BLUNT ABDOMINAL TRAUMA. Of course, more accurate tests should be in mind whenever clinical findings are incompatible with sonographic data, considering its low specificity and NPV. DPL still, is a safe and accurate method for evaluating BLUNT ABDOMINAL TRAUMA victims. Laparotomy without any diagnostic procedure yields more negative results.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    JAFARIAN, ALI, ASGARI, A., & EMAMI RAZAVI, S.H.. (2004). ROLE OF DIAGNOSTIC TOOLS (SONOGRAPHY & DPL) IN BLUNT ABDOMINAL TRAUMA (A 5 YEARS REPORT). STUDIES IN MEDICAL SCIENCE (THE JOURNAL OF URMIA UNIVERSITY OF MEDICAL SCINCES), 15(2), 136-141. SID. https://sid.ir/paper/64273/en

    Vancouver: Copy

    JAFARIAN ALI, ASGARI A., EMAMI RAZAVI S.H.. ROLE OF DIAGNOSTIC TOOLS (SONOGRAPHY & DPL) IN BLUNT ABDOMINAL TRAUMA (A 5 YEARS REPORT). STUDIES IN MEDICAL SCIENCE (THE JOURNAL OF URMIA UNIVERSITY OF MEDICAL SCINCES)[Internet]. 2004;15(2):136-141. Available from: https://sid.ir/paper/64273/en

    IEEE: Copy

    ALI JAFARIAN, A. ASGARI, and S.H. EMAMI RAZAVI, “ROLE OF DIAGNOSTIC TOOLS (SONOGRAPHY & DPL) IN BLUNT ABDOMINAL TRAUMA (A 5 YEARS REPORT),” STUDIES IN MEDICAL SCIENCE (THE JOURNAL OF URMIA UNIVERSITY OF MEDICAL SCINCES), vol. 15, no. 2, pp. 136–141, 2004, [Online]. Available: https://sid.ir/paper/64273/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top