مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

209
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

123
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid

Pages

  363-369

Abstract

 Background: Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through refractometer and strip in differentiation of exudates from transudates. Methods: The serum of patients was evaluated for protein, LDH, cholesterol, bilirubin and albumin. The fluid was evaluated for the number of white blood cells, protein, LDH, cholesterol, bilirubin and albumin. Then the fluids were divided into exduate and transudate categories based on Light and Gradient criteria. Finally, the specific gravity of the fluids was measured by refractometer, Erma, Japan and Medi-Test Combi II. The categorized fluids were compared with Gold Standards (final diagnosis) so that the sensitivity and specificity of Light and Gradient criteria in the transudate-exudate differentiation were specified. Results: In comparison with Light criteria, the cut off level of 1022 specific gravity measured by refractometer for pleural effusion has sensitivity, specificity of 92. 1%, 68. 1%respectively. In evaluation of peritoneal fluid considering cut off point 1023, measured by refractometer has reliable sensitivity 92. 4%, specificity 70. 4 compared with standard gradient method. Conclusion: Differentiating transudate from exudates by measuring its special gravity by refractometer will have acceptable sensitivity and specificity, and when rapidity is necessary or access to lab equipment is limited, this method could be used.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    NOZARIAN, ZOHREH, & ABDOLLAHI, ALIREZA. (2016). Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid. IRANIAN JOURNAL OF PATHOLOGY (IJP), 11(4), 363-369. SID. https://sid.ir/paper/717684/en

    Vancouver: Copy

    NOZARIAN ZOHREH, ABDOLLAHI ALIREZA. Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid. IRANIAN JOURNAL OF PATHOLOGY (IJP)[Internet]. 2016;11(4):363-369. Available from: https://sid.ir/paper/717684/en

    IEEE: Copy

    ZOHREH NOZARIAN, and ALIREZA ABDOLLAHI, “Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid,” IRANIAN JOURNAL OF PATHOLOGY (IJP), vol. 11, no. 4, pp. 363–369, 2016, [Online]. Available: https://sid.ir/paper/717684/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button