مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

1,724
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

SENSITIVITY AND SPECIFICITY OF NST IN CASES WITH DECREASE OF FETAL MOVEMENT AND AMNIOTIC FLUID VOLUME

Pages

  7-10

Abstract

 BACKGROUND AND OBJECTIVE: Non Stress Test (NST) is the most common test before delivery that is done in some cases with probability of fetal distress. The objective of this study was to determine the sensitivity and specificity of NST in cases with complaint of decreased FETAL MOVEMENT or decrease of amniotic fluid volume according to sonography report.METHODS: This cross- sectional study was done on 120 women referred to Bahonar hospital in Kerman. It was performed on all pregnant women with gestational age of 38-42 who complained of decrease of FETAL MOVEMENT and a decrease of amniotic fluid volume was reported in their sonography. FINDINGS: The result of NST in 64.1% of patients was nonreactive and in 35.9% was reactive. 41.7% of cases were with fetal distress during labor or delivery, of which 94.1% had nonreactive NST. The sensitivity and specificity of NST in cases with decrease of amniotic fluid were 89% and 74.5%, respectively and in cases with complaint of decreased FETAL MOVEMENT were 63.4% and 32%, respectively.CONCLUSION: Exact heart rate monitor in cases with complaint of decreased FETAL MOVEMENT or amniotic fluid volume and also with nonreactive NST is necessary

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    NADERI, T., NIKIAN, Y., & AMINZADEH, F.. (2002). SENSITIVITY AND SPECIFICITY OF NST IN CASES WITH DECREASE OF FETAL MOVEMENT AND AMNIOTIC FLUID VOLUME. JOURNAL OF BABOL UNIVERSITY OF MEDICAL SCIENCES (JBUMS), 4(1 (13)), 7-10. SID. https://sid.ir/paper/73277/en

    Vancouver: Copy

    NADERI T., NIKIAN Y., AMINZADEH F.. SENSITIVITY AND SPECIFICITY OF NST IN CASES WITH DECREASE OF FETAL MOVEMENT AND AMNIOTIC FLUID VOLUME. JOURNAL OF BABOL UNIVERSITY OF MEDICAL SCIENCES (JBUMS)[Internet]. 2002;4(1 (13)):7-10. Available from: https://sid.ir/paper/73277/en

    IEEE: Copy

    T. NADERI, Y. NIKIAN, and F. AMINZADEH, “SENSITIVITY AND SPECIFICITY OF NST IN CASES WITH DECREASE OF FETAL MOVEMENT AND AMNIOTIC FLUID VOLUME,” JOURNAL OF BABOL UNIVERSITY OF MEDICAL SCIENCES (JBUMS), vol. 4, no. 1 (13), pp. 7–10, 2002, [Online]. Available: https://sid.ir/paper/73277/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button