مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

804
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

THE EFFECT OF EXPOSURE FACTORS ON RELIABILITY OF VOXEL VALUES FROM CONE-BEAM COMPUTED TOMOGRAPHY ON DENSITY EVALUATION

Pages

  309-316

Abstract

 Introduction: Several factors affect the success rate of dental implants, including the quality of bone. Schwartz for the first time described the use of COMPUTED TOMOGRAPHY (CT) to classify bone density. CONE-BEAM CT (CBCT) has replaced CT in various fields due to lower dose and cost. This study aimed to evaluate the effect of exposure factors on reliability of CBCT in determining density.Materials & Methods: In this study, CT dose index phantoms including nine different concentrations of 76% meglumine with active ingredient of iodine were subjected to CBCT imaging with Planmecca 3D Mid under different exposure conditions. To obtain Hounsfield unit from CT, CT imaging from the phantoms was performed under standard conditions. Hounsfield unit and voxel values from CBCT and CT were recorded under all conditions, then, the difference and correlation between them was evaluated using paired-samples t-test and linear regression.Results: The results of this study showed excellent correlation between voxel values from CBCT and Hounsfield unit from CT (R=0.847). With changing the kVp conditions and mA this correlation remained high (R>0.8). There was no significant difference between the voxel values from CBCT and Hounsfield unit from CT under standard exposure conditions (P=0.6). However, variation in the amount of radiation exposure factors caused a significant change in CT and CBCT values, which could affect reliability of voxel values from CBCT (P=0.049).Conclusions: Our findings exhibited no significant difference between voxel values from CBCT and Hounsfield unit from CT. Furthermore, changes in exposure factors can affect the reliability of voxel values.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    ANBIAEE, NAJMEH, SANAEI FARROKHY, ALIREZA, & AKHLAGHI, SAEID. (2017). THE EFFECT OF EXPOSURE FACTORS ON RELIABILITY OF VOXEL VALUES FROM CONE-BEAM COMPUTED TOMOGRAPHY ON DENSITY EVALUATION. JOURNAL OF MASHHAD DENTAL SCHOOL, 40(4), 309-316. SID. https://sid.ir/paper/74140/en

    Vancouver: Copy

    ANBIAEE NAJMEH, SANAEI FARROKHY ALIREZA, AKHLAGHI SAEID. THE EFFECT OF EXPOSURE FACTORS ON RELIABILITY OF VOXEL VALUES FROM CONE-BEAM COMPUTED TOMOGRAPHY ON DENSITY EVALUATION. JOURNAL OF MASHHAD DENTAL SCHOOL[Internet]. 2017;40(4):309-316. Available from: https://sid.ir/paper/74140/en

    IEEE: Copy

    NAJMEH ANBIAEE, ALIREZA SANAEI FARROKHY, and SAEID AKHLAGHI, “THE EFFECT OF EXPOSURE FACTORS ON RELIABILITY OF VOXEL VALUES FROM CONE-BEAM COMPUTED TOMOGRAPHY ON DENSITY EVALUATION,” JOURNAL OF MASHHAD DENTAL SCHOOL, vol. 40, no. 4, pp. 309–316, 2017, [Online]. Available: https://sid.ir/paper/74140/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button