مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

96
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

69
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

Challenges of Plate Fixation for Vancouver Type-C fractures after a Well-fixed Hip Arthroplasty Femoral Stem (LETTER TO THE EDITOR)

Pages

  571-572

Keywords

Not Registered.

Abstract

 Dear Editor The fixation of distal femoral fractures (Vancouver type-C fractures; Figure A) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the interprosthetic biomechanical effects (e. g., negative, positive, and torsional strains). Surgeons have adopted a range of constructs, such as distal femoral locking plate, to overcome these difficulties. To minimize the risk of interprosthetic fracture between the femoral stem and femoral plate, many surgeons prefer to overlap the lateral plate with the tip of the well-fixed femoral stem or the proximal femoral component, along with soft tissue sparing techniques using long plates [Figure B]. On the other hand, other surgeons prefer to separate (non-overlap) the plate from the femoral stem. However, the superiority of overlapping the plate over non-overlapping is not well demonstrated in any highquality studies...

Cites

  • No record.
  • References

    Cite

    APA: Copy

    Ganji, reza. (2019). Challenges of Plate Fixation for Vancouver Type-C fractures after a Well-fixed Hip Arthroplasty Femoral Stem (LETTER TO THE EDITOR). THE ARCHIVES OF BONE AND JOINT SURGERY, 7(6), 571-572. SID. https://sid.ir/paper/755854/en

    Vancouver: Copy

    Ganji reza. Challenges of Plate Fixation for Vancouver Type-C fractures after a Well-fixed Hip Arthroplasty Femoral Stem (LETTER TO THE EDITOR). THE ARCHIVES OF BONE AND JOINT SURGERY[Internet]. 2019;7(6):571-572. Available from: https://sid.ir/paper/755854/en

    IEEE: Copy

    reza Ganji, “Challenges of Plate Fixation for Vancouver Type-C fractures after a Well-fixed Hip Arthroplasty Femoral Stem (LETTER TO THE EDITOR),” THE ARCHIVES OF BONE AND JOINT SURGERY, vol. 7, no. 6, pp. 571–572, 2019, [Online]. Available: https://sid.ir/paper/755854/en

    Related Journal Papers

  • No record.
  • Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button