مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

4,972
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

LENGTH DISCREPANCY FOLLOWING FEMUR FRACTURE PLATING IN CHILDREN

Pages

  11-17

Abstract

 Background: Treatment of FEMORAL FRACTURES in CHILDren sometimes requires open reduction and plate fixation. There is potential for complication in any type of fixation, leg length discrepancy being one of them. We are reporting the results of plate fixation, with special emphasis on limb length inequality problem.Materials: In a cross-sectional study, 42 patients at 6-12 years of age with femoral shaft fractures treated dynamic compression plate fixation were assessed for malunion, nonunion, infection, device failure, and limb length discrepancy in a mean follow-up of 26 months (18-60 months). Physical examination, serial X-rays and scanogram were used for assessment. Results: Out of the 42 cases, 32 (76.2%) were boys and the remaining 10(23.8%) were girls. Seven patients had comminuted fractures, 5 fractures were open Gustillo type 1. Twenty four were associated with polytrauma. The mean limb length discrepancy at the end of treatment was 1.17 centimeters (0.4-2.4 centimeters). There were no device failure, malunion, or infection.Conclusion: Treatment of paediatric femoral shaft fracture with dynamic compression plating has minimal side effects and causes minimal, if any, inequality in the length of the femur.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    MIRZATOLOUEI, FARDIN, AFSHAR, A.R., SARHADIAN, R., & SHISHAVI, F.. (2009). LENGTH DISCREPANCY FOLLOWING FEMUR FRACTURE PLATING IN CHILDREN. IRANIAN JOURNAL OF ORTHOPAEDIC SURGERY, 7(1 (26)), 11-17. SID. https://sid.ir/paper/85547/en

    Vancouver: Copy

    MIRZATOLOUEI FARDIN, AFSHAR A.R., SARHADIAN R., SHISHAVI F.. LENGTH DISCREPANCY FOLLOWING FEMUR FRACTURE PLATING IN CHILDREN. IRANIAN JOURNAL OF ORTHOPAEDIC SURGERY[Internet]. 2009;7(1 (26)):11-17. Available from: https://sid.ir/paper/85547/en

    IEEE: Copy

    FARDIN MIRZATOLOUEI, A.R. AFSHAR, R. SARHADIAN, and F. SHISHAVI, “LENGTH DISCREPANCY FOLLOWING FEMUR FRACTURE PLATING IN CHILDREN,” IRANIAN JOURNAL OF ORTHOPAEDIC SURGERY, vol. 7, no. 1 (26), pp. 11–17, 2009, [Online]. Available: https://sid.ir/paper/85547/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button