مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

693
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

Information Journal Paper

Title

INFLUENCE OF COMPENSATOR THICKNESS AND FIELD SIZE ON THE EFFECTIVE ATTENUATION COEFFICIENT OF A BRASS COMPENSATOR FOR INTENSITY-MODULATED RADIATION THERAPY

Pages

  61-70

Abstract

 One of the INTENSITY MODULATED RADIATION THERAPY (IMRT) methods is based on using COMPENSATORS. The most important factor in designing a compensator is the accurate calculation of its thickness to achieve the intensity modulation of interest. To achieve that, the exact attenuation coefficient of compensator materials must be calculated. Using Map CHECK 2 model 1177 and phantom (SP34). We studied the effect of compensator thickness and field size on the calculation of the EFFECTIVE ATTENUATION COEFFICIENT (EAC) of the BRASS compensator for 6-MV photon beams. Experimental measurements were carried out at 100 cm source-to-surface distance and 5 cm depth for the 6-MV photon beams of an Elekta linac using various field size and compensator thickness. The field sizes investigated ranged from 1×1 cm2 to 20×20 cm2 and the BRASS compensator thickness from 0.5-6 cm. Our results indicated that the compensator thickness and field size have the most significant effect on the calculation of the compensator EAC for the 6-MV photon beam and also these parameters can reduce the error due to delivered dose to target volume and organs at risk.

Cites

  • No record.
  • References

  • No record.
  • Cite

    APA: Copy

    BALVASI, E., HAGHPARAST, A., & HEJAZI, P.. (2016). INFLUENCE OF COMPENSATOR THICKNESS AND FIELD SIZE ON THE EFFECTIVE ATTENUATION COEFFICIENT OF A BRASS COMPENSATOR FOR INTENSITY-MODULATED RADIATION THERAPY. JOURNAL OF ILAM UNIVERSITY OF MEDICAL SCIENCES, 24(4), 61-70. SID. https://sid.ir/paper/90159/en

    Vancouver: Copy

    BALVASI E., HAGHPARAST A., HEJAZI P.. INFLUENCE OF COMPENSATOR THICKNESS AND FIELD SIZE ON THE EFFECTIVE ATTENUATION COEFFICIENT OF A BRASS COMPENSATOR FOR INTENSITY-MODULATED RADIATION THERAPY. JOURNAL OF ILAM UNIVERSITY OF MEDICAL SCIENCES[Internet]. 2016;24(4):61-70. Available from: https://sid.ir/paper/90159/en

    IEEE: Copy

    E. BALVASI, A. HAGHPARAST, and P. HEJAZI, “INFLUENCE OF COMPENSATOR THICKNESS AND FIELD SIZE ON THE EFFECTIVE ATTENUATION COEFFICIENT OF A BRASS COMPENSATOR FOR INTENSITY-MODULATED RADIATION THERAPY,” JOURNAL OF ILAM UNIVERSITY OF MEDICAL SCIENCES, vol. 24, no. 4, pp. 61–70, 2016, [Online]. Available: https://sid.ir/paper/90159/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top
    telegram sharing button
    whatsapp sharing button
    linkedin sharing button
    twitter sharing button
    email sharing button
    email sharing button
    email sharing button
    sharethis sharing button