مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Verion

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

video

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

sound

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Persian Version

Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View:

4,305
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Download:

0
Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

Cites:

2

Information Journal Paper

Title

MODIFICATION OF BOSTWICH METHOD TO DETERMINE TOMATO CONCENTRATES CONSISTENCY

Pages

  153-160

Abstract

 Tomato concentrated products were diluted up to 12 percent solids to measure their consistency by BOSTWICH CONSISTOMETER. The evaluation of the consistency of TOMATO CONCENTRATEd with different Brixes showed that the error in consistency measurement of TOMATO CONCENTRATEd by Bostwich method increased as the Brix increased. The studies indicated that the drying rate of insoluble solids and the lacking of reconstituting properties of them were caused error in the measurement of paste consistancy (especially at high Brixes). In this research, the effect of variety, TOMATO CONCENTRATEd Brix and the temperature of consistency measurement were evaluated to determine the error changes in BOSTWICH CONSISTOMETER and to modify it. The results showed that the variety had no effect on the accuracy of consistency measurement by Bostwich method, but Brix and temperature had a very significant effect on the accuracy of this assay and thus the error of BOSTWICH CONSISTOMETER increased, especially at high Brixes. It was concluded that heating of diluted TOMATO CONCENTRATEd (up to 45 Co) and then cooling it can decrease the error of consistency measurement considerably. Also, the consistency can be estimated accurately by using the regration between Brix, temperature and Bostwich consistency (R2=0.94).

Cites

References

  • No record.
  • Cite

    APA: Copy

    MAZAHERI TEHRANI, M., MORTAZAVI, SEYED ALI, SHAHIDI, F., & NASIRI MAHALATI, MAHDI. (2002). MODIFICATION OF BOSTWICH METHOD TO DETERMINE TOMATO CONCENTRATES CONSISTENCY. JOURNAL OF AGRICULTURAL SCIENCES AND NATURAL RESOURCES, 9(1), 153-160. SID. https://sid.ir/paper/9623/en

    Vancouver: Copy

    MAZAHERI TEHRANI M., MORTAZAVI SEYED ALI, SHAHIDI F., NASIRI MAHALATI MAHDI. MODIFICATION OF BOSTWICH METHOD TO DETERMINE TOMATO CONCENTRATES CONSISTENCY. JOURNAL OF AGRICULTURAL SCIENCES AND NATURAL RESOURCES[Internet]. 2002;9(1):153-160. Available from: https://sid.ir/paper/9623/en

    IEEE: Copy

    M. MAZAHERI TEHRANI, SEYED ALI MORTAZAVI, F. SHAHIDI, and MAHDI NASIRI MAHALATI, “MODIFICATION OF BOSTWICH METHOD TO DETERMINE TOMATO CONCENTRATES CONSISTENCY,” JOURNAL OF AGRICULTURAL SCIENCES AND NATURAL RESOURCES, vol. 9, no. 1, pp. 153–160, 2002, [Online]. Available: https://sid.ir/paper/9623/en

    Related Journal Papers

    Related Seminar Papers

  • No record.
  • Related Plans

  • No record.
  • Recommended Workshops






    Move to top